Date: 2021-01-13
Version: 1.5
Observe the disposal instructions for release agent and filters!
6.5
Replacing the diaphragm pump
Replace the diaphragm pump as follows:
1. Switch off the central lubrication unit off at its local switch.
2. Disconnect all hoses.
3. Release the fastening screws.
4. Remove the diaphragm pump from the central lubrication unit.
5. Fit a new diaphragm pump to the central lubrication unit.
6. Tighten the fastening screws.
7. Reconnect all hoses.
8. Set the intake air valve.
9. Switch the central lubrication unit into automatic mode.
6.6
Dealing with faults and fault indication
Removal of faults
Faults which are not removed or removed improperly can lead to faulty products,
damages to the plant or personal and property damage in adjoining areas!
Faults influence directly the proper operation of the plant! Faults have to be analysed
and removed immediately!
6.6.1
ZSD interrupts delivery
If the applied compressed air values do not meet requirements or the supply lines are damaged,
the valve switches incorrectly or remains in its switching position. Check for possible defects
and re-establish the operational values. Replace any defective components.