Led Specifications 2; Cautions And Warnings - Fortinet FortiSwitch 1048D Quick Start Manual

Table of Contents

Advertisement

LED Specifications 2

1
3
5
7
9
11
13
15
17
19
21
23
2
4
6
8
10
12
14
16
18
20
22
24
2
# LED
State
Green
1 FAN
Yellow
Green
Power
Yellow
2
Supplies
Off
3 FAN
25
27
29
31
33
35
37
39
41
43
45
47
26
28
30
32
34
36
38
40
42
44
46
48
49
3
Description
Fans are operating normally.
A fan has failed.
The power supply is receiving power.
Power has been lost; a parallel power
supply still has power.
The power supply has no power.
This LED is not in use.
Page 10

Cautions and Warnings

Environmental specifications
1
Operating Temperature – If this device is installed in a closed or multi-unit rack assembly,
the rack's ambient temperature may be greater than the room's ambient temperature. Make
PWR1 PWR2 SYSTEM FAN
MGMT
sure the rack environment is compatible with the manufacturer's maximum rated ambient
CONSOLE
temperature (T
).
50
51
52
ma
Température ambiante élevée — Si cet appareil est installé dans un cabinet fermé, la
2
température ambiante du cabinet peut être supérieure à la température ambiante de la pièce.
Assurez- vous que l'environnement dans le cabinet est compatible avec la température
ambiante maximale du fabricant (T
Air flow – For rack installation, make sure that the amount of air flow required for safe
operation of the equipment is not compromised. For free-standing installation, make sure that
the appliance has at least 2 inches (5 cm) of clearance on each side to allow for adequate air
flow and cooling.
Ventilation — Pour une installation dans un cabinet, assurez-vous que la ventilation nécessaire
au fonctionnement de l'équipement n'est pas compromise. Pour une installation autonome,
assurez-vous que l'appareil dispose d'au moins 2 pouces (5 cm) de dégagement de chaque
côté pour permettre l'écoulement de l'air et un refroidissement adéquat.
Circuit overloading – To avoid overloading, use the ratings on the label. Consider the
equipment's connection to the supply circuit and the effect that circuit overloading might have
on current protection and supply wiring.
For redundant power sources, connect each to an IEC/UL Listed power source whose output
rating is greater than or equal to the equipment.
Surtension – Pour éviter de surcharger le circuit d'alimentation, référez-vous aux notes sur
l'étiquette de l'équipement . Envisagez l'effet que la surtension du circuit pourrait avoir sur la
protection de surtension et le câblage d'alimentation .
Pour les sources d'alimentation redondantes, connectez chacun à une source d'alimentation
Mis CEI / UL dont la cote de rendement est supérieur ou égal à l'équipement.
Reliable earthing – Make sure all rack-mounted equipment is grounded. This includes supply
connections (e .g . power strips), not only direct connections to the branch circuit.
Mise à la terre – Assurez-vous que tout l'équipement est mis à la terre . Ceci comprend les
connexions d'alimentation (par exemple, les barres d'alimentation) en plus des connexions
directes au circuit de dérivation.
Interference – If possible, use Shielded Twisted Pair (STP) Ethernet cables instead of
Unshielded Twisted Pair (UTP) .
Interférence – Si possible, utilisez des câbles Ethernet de paire torsadée blindée (STP) plutôt
que de paire torsadée non blindée (UTP).
Refer to specific Product Model Data Sheet for Environmental Specifications (Operating
Temperature, Storage Temperature, Humidity, and Altitude).
).