(b) Remove the O-ring from the suction hose sub-assembly.
NOTICE:
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
15. REMOVE ELECTRIC INVERTER COMPRESSOR
(b) Disconnect the connector <B>.
2010 Toyota Prius
(a) Release the green-colored lock and disconnect the connector <A> as
shown in the illustration.
CAUTION:
Wear insulated gloves when performing the procedures.
NOTICE:
Insulate the connector by sealing it with tape.
Text in Illustration
*1
Green-colored Lock
(c) Remove the 3 bolts and electric inverter compressor.