About The Related Manuals - Mitsubishi Electric FR-A872-E Instruction Manual

Table of Contents

Advertisement

Symbol
Name
(a)
Plug-in option connector 1
(b)
Plug-in option connector 3
(c)
Plug-in option connector 2
Voltage/current input switch
(d)
(SW2)
Ethernet communication
(e)
connector
(f)
Control circuit terminal block
(g)
PU connector
(h)
USB A connector
(i)
USB mini B connector
Upper main circuit terminal cover
(j)
(front)
Upper main circuit terminal cover
(k)
(left)
Upper main circuit terminal cover
(l)
(right)
Main circuit terminal block (for
(m)
terminals P and N)
(n)
Upper front cover
(o)
Power lamp
(p)
Alarm lamp
(q)
Charge lamp
(r)
Operation panel (FR-DU08)
(s)
Lower front cover
Lower main circuit terminal block
(t)
cover
(u)
Cooling fan
Main circuit terminal block (for
(v)
terminals U, V, and W)
Switches (SW3 and SW4) for
(w)
manufacturer setting
*1
For details on how to remove the Ethernet board, refer to the Ethernet Function Manual.
*2
Refer to the Instruction Manual (Function).
1.3

About the related manuals

The manuals related to this product are shown below.
Manual name
FR-A870 Instruction Manual (Function)
FR-A800-E Ethernet Function Manual
FR-CC2-N Instruction Manual
FR-A800/F800 PLC Function Programming Manual
FR-A870 Safety Stop Function Instruction Manual
Connects a plug-in option or a communication option.
The connector 2 cannot be used because the Ethernet board is installed in the
initial status. The Ethernet board must be removed to install a plug-in option to
the connector 2. (However, Ethernet communication is disabled in that case.)
Selects between voltage and current for the input via terminals 2 and 4.
Connect the Ethernet dedicated cable for connection to the network.
Connects cables for the control circuit.
Connects the operation panel (FR-DU08) or the parameter unit (FR-PU07). This
connector also enables the RS-485 communication.
Connects a USB memory device.
The USB connection with a personal computer can be established.
Remove it when connecting cables to terminals P and N.
Connected to the converter unit.
Remove this cover for the installation of the product, installation of a plug-in
(communication) option, switching of the voltage/current input switches, etc.
Stays ON while the power is supplied to the control circuit (R1/L11, S1/L21).
Turns ON when the protective function of the inverter is activated.
Stays ON while the power is supplied to the main circuit.
Operates and monitors the inverter.
Remove this cover when removing the upper front cover.
Remove it when connecting cables to terminals U, V, and W.
Cools the inverter.
Connects cables for the main circuit.
Do not change the initial setting (OFF
IB-0600616ENG
IB-0600628ENG
IB-0600833ENG
IB-0600492ENG
BCN-A23228-017(E)
Description
OFF
).
ON
Manual number
1.3 About the related manuals
Refer to page
Instruction
1
Manual of the
option
*1
2
*2
3
58
41
57
4
58
58
5
21
6
35
7
21
36
86
8
36
*2
21
9
21
97
35
10
15
1. INTRODUCTION