Sanyo CM2472 Technical & Service Manual page 63

Conditioner air system-multi inverter dc
Hide thumbs Also See for CM2472:
Table of Contents

Advertisement

– Inverter Multi Split System Air Conditioner –
Contents
IMPORTANT!
Please Read Before Starting .................................. 2
1.
GENERAL .......................................................... 3
1-1. Tools Required for Installation (not supplied)
1-2. Accessories Supplied with Unit
1-3. Optional Copper Tubing Kit
1-4. Type of Copper Tube and Insulation Material
1-5. Additional Materials Required for Installation
2.
INSTALLATION SITE SELECTION ................... 4
2-1. Indoor Unit
2-2. Connecting Indoor Units
2-3. Outdoor Unit
2-4
Baffle Plate for the Outdoor Unit
(CLM models only)
2-5. Outer Dimensions of Outdoor Unit
2-6. Diagram of Outdoor Unit Installation
3.
INSTALLATION PROCESS .............................. 15
3-1. Embedding the Tubing and Wiring
3-2. Use of the Flaring Method
3-3. Flaring Procedure with a Flare Tool
3-4. Caution before Connecting Tubes Tightly
3-5. Tubing Connections
3-6. Insulation of Refrigerant Tubing
3-7. Taping the Tubes
3-8. Finishing the Installation
4.
AIR PURGING................................................... 18
I Air Purging with a Vacuum Pump (for Test Run)
I Pump Down
5.
WIRING INSTRUCTIONS ................................. 21
5-1. General Precautions on Wiring
5-2. Recommended Wire Length and Diameter
5-3. Wiring System Diagram
5-4. How to Connect Wiring to the Terminal
5-5. Wiring Instructions for the Outdoor Unit
6.
TEST RUN......................................................... 25
7.
CONNECTING A HOME AUTOMATION
DEVICE ............................................................. 26
8.
INSTALLATION CHECK SHEET ...................... 26
214
85264190
003 © SANYO 2007
INSTALLATION INSTRUCTIONS
This air conditioner uses the new refrigerant R410A.
Refrigerant service valve size = 5/16"
NOTE
Page
SANYO Commercial Solutions
A Division of SANYO North America Corporation
Cornerstone Business Park,
1062 Thorndale Avenue,
Bensenville, IL 60106, U.S.A.
Model Combinations
Combine indoor and outdoor units only as listed
below.
Indoor Unit
KMS0772
KMS0972
KMS1272
KMS1872
KMS2472
Combine indoor and outdoor units only as listed in
the combination tables for 3-room or 4-room
outdoor unit as shown in its respective manual.
Power Source:
60 Hz, single-phase, 230 / 208 VAC
Be sure to read the yellow instruction sheet
attached to the outdoor unit for models using the
new refrigerant R410A.
Combination example
Indoor unit B
Indoor unit A
Outdoor unit
Indoor unit D
NOTE
The illustrations are based on the typical appearance of
a standard model. Consequently, the shape may differ
from that of the air conditioner that you are installing.
For Outdoor Unit
COOL / DRY Model
Outdoor Unit
CM1972
CM2472
CM3172
CLM1972
CLM2472
CLM3172
Indoor unit C
In Canada
SANYO Canada Inc.
1-300 Applewood Crescent, Concord
Ontario, L4K 5C7, Canada