Sundance Spas Edison Owner's Manual page 48

Hide thumbs Also See for Edison:
Table of Contents

Advertisement

680 SERIES
Figure 3
8
3. Remove the black bulb boot (8) by sliding it over the cable away from
the quartz seal compression nut (7), Figure 3.
4. Slowly remove the UV bulb (4) out of the quartz tube.
5. Remove bulb socket (5) from the UV bulb (4), Figure 4.
6. Remove the quartz seal compression nut (7) by turning it
counterclockwise, Figure 3. Use a pair of channel-lock pliers if
needed, Figure 5. You will notice that there is a
stainless steel compression washer (6) that slides
over the quartz tube. Save the washer (6) for later
use, Figure 6. There is also a black seal ring (13),
grasp the black seal ring; slowly and carefully
remove the quartz tube.
7. Now you are ready to clean or replace the quartz tube (2). For the
cleaning of the quartz tube (2), follow steps 8 and 9 then proceed to step
10. For replacing of the quartz tube (2), skip steps 8 and 9 and proceed
to step 10.
8. Cleaning quartz tube: Clean the quartz tube by wiping until clear
using a paper towel or a dry cotton cloth. If needed a household tub
and shower lime removal product can be used.
WARNING:
!
scratch the quartz tube surface.
9. Rinse the quartz tube with clean water to completely remove any
cleaning products that were used in step 4.
10. Replacing quartz tube: You will notice that the new quartz tube does
not have a black cushion on the domed end as the old quartz tube
does. This is normal as the cushion was provided with the original
quartz tube to protect it from breakage during transportation. Install the
black seal ring (13) over the opened end of the quartz tube. Place the
new quartz tube (2) into the water chamber (1) with the domed end
first making sure it is inserted and seated inside the quartz end holder.
Only a small portion will be exposed when it is seated correctly.
11. Reinstall the compression washer (6) over the open end of the quartz
tube (2). Push it against the quartz black seal ring (13).
12. Reinstall and hand tighten the quartz seal compression nut (7) by
turning it clockwise.
13. Refill your spa.
Page 42
7
Figure 4
4
Do not use abrasive cleaners as they can
4
5
Figure 5
2
13
7
6
Figure 6