Rv Installation Appendix - Dometic MasterFlush 8740 Installation Manual

Macerator toilet
Hide thumbs Also See for MasterFlush 8740:

Advertisement

Dometic 8700 Series MasterFlush Toilet
5.5
Toilet system with through-the-wall
connections
1 . To route wiring and plumbing connections through the wall, use
floor template to locate the vertical centerline of each hole .
2 . Place toilet in proper position and mark horizontal centerlines
21
(fig .
) .
3 . Drill holes sizes as indicated on template .
4 . Route wiring and plumbing through holes, then follow toilet
installation instructions beginning at Section 5.3 or Section 5.4,
step 4 .
6

RV installation appendix

Wiring / Electronic Control Module Connections
Warning!
Hazard of Shock or Fire: Always use recommended fuse, circuit breaker and wire size .
Failure to do so can cause the loss of property and life .
Installation notes
Each toilet must have its own circuit breaker or fuse .
Wire sizes must be appropriate for the installation . All other installation factors must be in accordance
with ISO electrical standards .
Always use stranded copper wire (preferably tinned) .
Always use crimp-type wire connections . Do not use wire nuts (they corrode) .
When installing a Dometic macerator toilet in a recreation vehicle, please use the following wiring
information .
WIRE SIZING CHART
Wire size per length of run*
12 volts DC
* Distance from circuit breaker to electronic control module .
CONVERSION TABLE
Wire – AWG to mm
AWG
14
mm
2 .5
2
0-15 ft.
#14
Feet to Meters
2
12
10
Ft
4 .0
6 .0
M
16-30 ft.
31-50 ft.
#12
#10
10
15
20
3 .1
4 .6
6 .1
Installation
21
30
50
9 .2
15 .2
11