Safety Precaution; Insulation Resistance Test - Panasonic SX-PR804P Service Manual

Digital ensemble
Table of Contents

Advertisement

2. Parts which have a
for safety. When replacing these parts, be sure to use only the specified parts.
3. Use the specified types for internal wiring (double-insulated wiring, etc.).
4. When replacing parts on the AC primary side (power transformer, electric switch,
electrical cord, noise-prevention condenser, etc.), wind the lead wire and secure it
by soldering.
5. Do not let the wiring come into contact with heat-emitting devices (fuse resistor,
radiator plate, etc.).
6. When replacing the wiring, make sure that it is not in contact with the unfinished or
rough edge of a part.
7. When replacing the power cord (except for the plug-in type), tug it from various
directions to confirm that it does not slip out of place.
8. Spacing
If soldering was done on the AC primary circuit, confirm that the interval between
the soldered terminals or between the terminal and surrounding metallic parts is at
least the minimum required (between the primary circuit and the chassis: atleast
6.5 mm; between primary circuit terminals: at least 4.0 mm; between primary
circuit terminals and secondary circuit terminals: at least 6.5 mm.).

2. SAFETY PRECAUTION

2.1. Safety precaution
1. Before servicing, unplug the power cord to prevent an electric shock.
2. When replacing parts, use only the manufacturer's recommended components for
safety.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation
papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to make the
following insulation resistance test to prevent the customer from being exposed to
a shock hazard.

2.2. Insulation resistance test

1. Unplug the power cord and short the prongs of the plug with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with an ohmmeter between the jumpered AC plug and
each exposed metal cabinet part, such as screw heads, connectors, control shafts,
mark in the circuit diagram or in the parts list are essential