INSTALLATION PROCEDURE

NOTE: For installations in Australia and New Zealand, product must
be installed with a backflow prevention device in accordance with
AS/NZS 3500 and AS/NZS 2845.1.
1. The predrilled mounting holes in the bracket can be used as a
guide. The holes are on 16" centers. Mark and insert anchors or
screws in the wall.
2. Mount the manifold using four (4) screws in the bracket mounting
holes. The slots will accept a 3/8" diameter lag bolt or screw.
3. Do not connect the treated water outlet ports to the equipment
being served until after the system has been flushed ("Figure 1").
Manifold
Inlet Valve
To Storage
HFUF Rinse
Tank
Valve 3/8"
Barb
3/4" Female
NPT Inlet
Valve
HFUF
Flush Line
Sanitizing
Port Valve
Housing Flush
Line Connector
4. Attach one of the supplied 3/8" I.D. tubing to the fitting on the
HFUF Flush Valve ("Figure 1"). Use one of the spring clamps to
secure. Run the other end of the tubing to a drain.
5. Attach the second piece of 3/8" I.D. tubing to the fitting on the
Manifold Rinse Valve ("Figure 1"). Use one of the spring clamps to
secure. Run the other end to a drain.
4 • PENTAIR® EVERPURE® SC HIGH-FLOW WATER FILTRATION SYSTEMS INSTALLATION, OPERATION & MAINTENANCE GUIDE
11.8"
(30)
19.1"
(48.4 cm)
34.7"
(88.1 cm)
18.8"
(47.8cm)
Treated Water Outlet
3/4" NPT
2SR-BW
Feed Valve
Scale Inhibitor
Outlet
1/2" Barb
Manifold
Rinse Valve
3/8" Barb
To Drain
3/4" ID
Figure 1
NOTE: Some plumbing codes require an air gap at the drain termination.
6. The Everpure 2SR-BW Cartridge has a shut-off valve on the
inlet. Do not attach the tubing to the ice maker or hot beverage
application at this time. Attach short tube for flushing.
7. Turn off the flow valves shown in "Figure 1"":
• Inlet
• HFUF Rinse
• Manifold Inlet
8. The HFUF cartridge is shipped inside the housing. Locate the
bag with the housing and cartridge. Open the bag and remove
the housing with the HFUF cartridge still inside.
CAUTION: Do not remove the HFUF cartridge from the housing.
9. Remove one of the O-rings from its shipping bag. Lubricate O-ring
with the supplied silicone grease. Insert it into the cartridge
housing groove ("Figure 2") at the top edge of the housing.
10. Check to be sure the two (2) top O-rings of the HFUF cartridge are
sufficiently lubricated and in the grooves. Use included silicone
packets or a food-grade silicone lubricant, if needed. They should
be seated and clean of debris. Thread the housing into the head
by hand. Use a sump wrench to lightly tighten the housing onto
the head. This can be tightened further if leaks occur. The two (2)
O-rings at the top of the cartridge will fit snuggly into the head.
Thread housing flush line connector onto bottom of housing.
Hand tighten.
(2) O-rings
• Sanitizing
• Manifold Rinse
• Scale Inhibitor
Figure 2
Figure 3