Maintenance
4.
Slide pump assembly off the mounting
pins.
ProXChange Removal Tool
An integrated tool is included in the frame to
remove the ProXChange packing assembly.
See Pump repair manual for complete repair
instructions.
ti26931a
28
Inlet Valve Removal
An integrated tool is included in the frame to
remove the inlet valve assembly from the
pump. If you suspect that the inlet valve is
clogged or stuck, remove the valve assembly
and clean or replace.
1.
Remove suction tube or hopper from
sprayer.
2.
Insert pump inlet into frame and loosen
the inlet valve. Remove inlet valve.
ti26930a
ti27479a
Do not lose the ball and spring inside the inlet
valve assembly. It may fall out when the inlet
valve is removed. Pump will not prime without
the ball and spring.
3.
Clean any debris and dried paint from
the cavity and replace the ball and
spring. Tighten inlet valve to pump
using integrated tool on the frame.
NOTICE
ti27498a
3A3242C