16
. CHARGING SYSTEM

BATTERY

REMOVAL
Open the seat and battery cover.
First disconnect the battery negative cable
and then the positive cable.
Remove the battery.
When disconnecting the battery positive
(+) cable, do not touch the frame with
tool; otherwise it will cause short circuit
and sparks to damage the battery and
ignite the gasoline.
The installation sequence is the reverse of
removal.
First connect the positive (+) cable and then
the negative (-) cable to avoid short circuit.
BATTERY VOLTAGE (OPEN CIRCUIT
VOLTAGE) INSPECTION
Remove the left side cover.
Disconnect the battery cables.
Measure the voltage between the battery
terminals.
Fully charged : 13.1V
Undercharged: 12.3V
Battery charging inspection must be
performed with a voltmeter.
CHARGING
Connect the charger positive (+) cable to the
battery positive (+) terminal.
Connect the charger negative (-) cable to the
battery negative (-) terminal.
• Keep flames and sparks away from a
charging battery.
• Turn power ON/OFF at the charger, not
at the battery terminals to prevent
sparks near the battery to avoid
explosion.
• Charge the battery according to the
current specified on the battery.
• Quick charging should only be done in
an emergency.
• Measure the voltage 30 minutes after
the battery is charged.
Charging current: Standard : 0.5A
Charging time
: Standard : 5~10 hours
After charging: Open circuit voltage: 12.8V min.
NEXXON 50
Terminal (+)
Battery
16-4