1-16. COMPRESSOR PREHEATING

When the outdoor temperature is lower than 0°C and the all operation mode has been
stopped for 30 minutes, power is applied to the compressor and the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started and when the outdoor temperature rises to 25°C or greater,
preheating is ended.
1-17. 10
C HEAT OPERATION
°
The 10°C HEAT operation
The 10°C HEAT
operation can be set by the wireless remote controller.
The 10°C HEAT
operation is almost the same operation as below settings.
( Table9 )
Mode
Setting temperature
Fan mode

1-18. ECONOMY OPERATION

The ECONOMY operation functions by pressing ECONOMY button on the remote controller.
The ECONOMY operation is almost the same operation as below settings.
( Table10)
Mode
Target temperature
functions by pressing 10°C.HEAT button on the remote controller.
Heating
10°C
AUTO
Cooling/ Dry
Setting temp.+1°C
Setting temp.-1°C
01-18