Connection diagram
220V-240V
220V-240V
Insert the shunts
Main power connection 1-
phase
L
N
Wiring colours:
Yellow / green
N
Blue
L
Black or brown
Tighten the terminal screws
securely!
Once you connect the hob to the mains,
check if all the cooking zones are ready to
use. Place a pot with some water on a
cooking zone and set the power setting for
each zone to the maximum level for a short
time.
400V 2N
L1 L2
N
PE
between the screws as shown.
Main power connection 2-
phase
L1 L2 L3 N
Wiring colours:
Yellow / green
N
Blue
L1
Black
L2
Brown
220V-240V 1N
L
N PE
220V-240V
Main power connection 2-phase
without neutral
Wiring colours:
F1
F2
If
or
the display after you switch on
the hob for the first time, refer to
"Troubleshooting".
220V-240V
F1
F2
PE
220V-240V
F1
F2
Yellow / green
Black
Brown
symbol comes on