Error code
Remote control:
E11
1. Applicable model
All models
2. Error detection method
IU address has been set using
the "Master IU address set"
function of remote control.
3. Condition of Error displayed
Same as above
4. Presumable cause
Same as above
Note:
LED
Green
Red
Keeps flashing
Indoor
Keeps flashing
Keeps flashing
stays OFF
Outdoor
5. Troubleshooting
Diagnosis
E11 occurs
Is "Master IU
address set" function of remote
control used?
In case the wiring is below and "Master IU address set"
is used, E11 is appeared.
IU
IU
R/C
83
-
Content
Address setting error of
indoor units
YES
IU
-
'14 • PAC-SM-215
Countermeasure
• In cases of RC-E5
Return address No. to
"IU ..." using [ ▲ ] or
[ ▲ ] button.
• In cases of RC-EX1A
Menu ➞ Next
➞ IU settings ➞ Select IU