Error Messages - Lenovo ThinkPad X1 Series Hardware Maintenance Manual

Hide thumbs Also See for ThinkPad X1 Series:
Table of Contents

Advertisement

Table 2. Numeric error codes (continued)
Symptom or error
2101
Detection error on SSD1 (M.2)
2102
Detection error on SSD2 (M.2)
2110
Read error on HDD0 (Main HDD)
2111
Read error on SSD1 (M.2)
2112
Read error on SSD2 (M.2)
2200
Machine Type and Serial Number are invalid.
2201
Machine UUID is invalid.
2202
Brand Name is invalid.
2203
System configuration is invalid.
2204
System configuration data is invalid.

Error messages

Table 3. Error messages
Symptom or error
Fan error
Thermal sensing error
FRU or action, in sequence
1. Reseat the M.2 solid-state drive.
2. M.2 solid-state drive
3. System board
1. Reseat the M.2 solid-state drive.
2. M.2 solid-state drive
3. System board
1. Reseat the hard disk drive.
2. Hard disk drive
3. System board
1. Reseat the M.2 solid-state drive.
2. Main M.2 solid-state drive
3. System board
1. Reseat the M.2 solid-state drive.
2. Main M.2 solid-state drive
3. System board
System board
System board
Have the computer serviced.
Have the computer serviced.
Have the computer serviced.
FRU or action, in sequence
1. Fan
2. Thermal grease
3. System board
System board
Chapter 4
.
Related service information
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thinkpad x1 yoga gen 5Thinkpad x1 carbon gen 8

Table of Contents