Disassembly Procedures
!
WARNING

Diode/Circuit Protector

1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Discharge high voltage capacitor, (see "High Voltage
Capacitor" section).
3. Disconnect component from high voltage capacitor
and remove screw securing diode to ground.
4. Replace component and reverse procedure to
reassemble.

Transformer

1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Discharge high voltage capacitor, (see "High Voltage
Capacitor" section).
3. Disconnect and label wire leads from transformer.
4. Place unit on it's back to gain access to mounting
screws.
5. Remove screws securing transformer and remove.
6. Replace transformer and reverse procedure to
reassemble.
H.V
H.V
Transformer

Fuse / Fuse Block / Filter Assembly

1. Disconnect power to oven and remove outer case,
(see "Outer Case" section).
28
To avoid the risk of electrical shock, personal injury, or death,
disconnect power to oven and discharge the capacitors before
following any disassembly procedure.
2. Disconnect and label wires.
3. Carefully lift tabs to release assembly from plastic
4. Replace component(s) and reverse procedure to

Magnetron

Magnetrons are located on the side of the cavity.
1. Disconnect power to oven and remove outer case,
2. Discharge high voltage capacitor, (see "High Voltage
3. Remove terminal plug from filament terminals.
4. Remove screws securing duct assembly and place to
Blower Motor ASS'Y
5. Remove screws securing magnetron being replaced to
Suction
Guide
H.V
6. Replace magnetron and reverse procedure to
Transformer
NOTE: When replacing magnetron, make sure gasket is
16026086
locating pins.
reassemble.
!
CAUTION
Before replacing a blown monitor fuse, test the primary
interlock switch, secondary interlock switch, monitor
switch, and power relay contacts for proper operation.
If the monitor fuse is blown by a failed switch
operation, all switches and controller must be
replaced.
(see "Outer Case" section).
Capacitor" section).
the side to gain access to magnetrons.
the wave guide.
Chassis
reassemble.
in correct position and in good condition.
!
CAUTION
During replacement of magnetron, be certain the R.F.
anode gasket is in place around the anode stud.
!
WARNING
A microwave leakage test must be performed anytime
a magnetron assembly is removed, replaced,
disassembled, or adjusted for any reason.
Antenna
Gasket
Filament