Operation; Maintenance; Care; Drawings - Honeywell HERMetic PRESS Operation And Service Manual

Table of Contents

Advertisement

1. install the HERMetic PRESS on the HERMetic valve via the quick coupling device.
2. Open the valve. The HERMetic PRESS is then in direct contact with the tank atmosphere, and
pressure or vacuum is indicated on the manometer, which is graduated from - 1500 to + 2500
MM water column.
3. Read the pressure.
4. Close the valve.
5. Disconnect the HERMetic PRESS.
6. Clean the HERMetic PRESS before the next check.
7.1

Care

For long service life, keep the HERMetic Press clean and well lubricated and, when not in use,
store it in a dry and protected location.
To adjust the zero of the manometer, remove the rubber blanket and the top cover. Turn the
adjusting screw located in the centre of the manometer.
When ordering spare parts, always state the drawing and the item number.
ND
30275
30415
41039
50420/PRESS/1001

6. Operation

7. Maintenance

8. Drawings

TS
10069
10020
22564
DESCRIPTION
Press stainless steel 1" mmWC
Press stainless steel 1" mmWC
Adaptor 1"/2"