2-4. E: 18. External communication error (Indoor unit)
Indicator
Indoor unit
Detective actuator
Indoor unit
Forecast of cause
Check point 1. Check the connection
Check any loose or removed connection between the main PCB to the WLAN adapter.
-> If there is an abnormal condition, correct it by refer to the installation manual or the "DESIGN
& TECHNICAL MANUAL".
Check the connection condition on the WLAN adapter and the main PCB (If there is loose con-
nector, open cable or mis-wiring.)
Check point 2. Replace the WLAN adapter
If check point 1 do not improve the symptom, change WLAN adapter.
Check point 3. Replace the main PCB
If check point 2 do not improve the symptom, replace the main PCB.
2-4. E: 18. External communication error (Indoor unit)
Operation indicator
Timer indicator
Economy indicator
Error code
External
communication
error
End
Continuous flash
After receiving a signal from the external input and
output PCB, the same signal has not been received for
15 seconds.
Connection failure
WLAN adapter failure
- (03-25) -
1 time flash
8 time flash
E: 18
Main PCB