STOPPING THE ENGINE
Normal Shutdown
1. Place the engine throttle lever in the IDLE position
(Figure 14), and run the engine for three minutes at
low speed.
THROTTLE
LEVER
Figure 14. Throttle Lever (Idle)
2. After the engine has cooled, place the fuel valve lever
in the OFF position (Figure 15).
FUEL VALVE
LEVER
Figure 15. Engine Fuel Valve Lever (OFF)
NOTICE
When transporting the pump, ALWAYS place the
engine fuel valve lever in the OFF position.
QP3TB TRASH PUMP • OPERATION MANUAL — REV. #0 (12/08/22)— PAGE 19
Emergency Shutdown
Move the engine fuel valve lever quickly to the OFF
position (Figure 15).
OPERATION