Installing the water heater.
14
During Installation of this water heater...........
DO
DO check inlet gas pressure to ensure
that it is within the range specified on the
rating plate.
DO provide adequate air for combustion
and ventilation as discussed in the Use and
Care Manual and the National Fuel Gas
Code.
DO maintain proper clearances to
combustibles as specified on the rating plate.
DO ensure that the venting system
complies with the guidelines found in the
Use and Care Manual and National Fuel Gas
Code.
DO contact a qualified service technician
if the pilot or main burner will not stay
lit. The burner chamber is designed to be
sealed utilizing a gasket and tamper resistant
screws.
DON'T
DON'T block or restrict Combustion
Air Inlet Openings located around the lower
portion of the water heater jacket.
DON'T remove the Burner Access
Door unless absolutely necessary.
should only be done by a qualified service
technician. A new burner access door gasket
must be installed on any burner access door
that has been removed.
DON'T install this water heater where
standing water may occur. The base of the
water heater is meant to be mounted on a dry
surface.
DON'T operate the water heater if the
sight glass or pilot assembly door grommet
is damaged or broken.