Connection
6.8 Replacing a CLP
4. Remove the CLP from the slot.
5. Close the slot cover (torque 0.8 Nm) to ensure that the device maintains the degree of
protection IP30.
Inserting the CLP
To insert a CLP into the device, follow the steps below:
1. Turn off the power to the device.
2. Loosen the screws M3
3. The housing of the CLP has a rounded underside (B). Accordingly, the slot opening has a
rounded edge. Note this orientation when inserting the CLP.
Insert the CLP
4. Close the slot cover (torque 0.8 Nm) to ensure that the device maintains the degree of
protection IP30.
62
with a Torx screwdriver T10 and remove the slot cover
in the correct orientation into the slot.
B
Operating Instructions, 03/2023, C79000-G8976-C650-05
.