Electrical requirements

Observe all governing codes and ordinances.
A 120 Volt, 60 Hz, AC only, 20 amp fused
electrical supply is required. (A time-delay
fuse is recommended.) It is recommended
that a separate circuit serving only this
appliance be provided.

GROUNDING INSTRUCTIONS

For all cord connected appliances:
The microwave oven must be grounded.
In the event of an electrical short circuit,
grounding reduces the risk of electric
shock by providing an escape wire for
the electric current. The microwave oven
is equipped with a cord having a ground-
ing wire with a grounding plug. The plug
must be plugged into an outlet that is
properly installed and grounded.
WARNING
– Improper use of the
grounding can result in a risk of
electric shock.
Consult a qualified electrician or service-
man if the grounding instructions are not
6
wWARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions
can result in death, fire,
or electrical shock.
completely understood, or if doubt exists
as to whether the microwave oven is
properly grounded.
Do not use an extension cord. If the power
supply cord is too short, have a qualified
electrician or serviceman install an outlet
near the microwave oven.
For a permanently connected appliance:
The microwave oven must be connected
to a grounded, metallic, permanent wiring
system, or an equipment grounding
conductor should be run with the circuit
conductors and connected to the equip-
ment grounding terminal or lead on the
appliance.