Sennheiser SpeechLine IS Series Instruction Manual page 30

Microphone solutions for your conference, meeting room presentation
Table of Contents

Advertisement

Connecting the products
B) Connecting microphones to a DSP with logic function
To establish a logic connection in addition to the audio connection:
Use a 3-wire cable (Ø 0.14–0.5 mm
table stand to a GPIO port or logic port of the DSP.
Lay all cables in such a way that other persons cannot trip over them
and injure themselves.
Observe the connection instructions in the instruction manual of your
DSP.
MEB 114-S
Set the slide switch for setting the behavior of the microphone button
to
ON
in order to activate the "DSP remote mode".
In "DSP remote mode", the microphone is permanently on and is muted
or activated via the DSP. The microphone thus permanently provides a
reference signal for AEC algorithms in the DSP.
MAT 133-S
MAT 153-S
2
) to connect the microphone or the
DSP
logic
MAT 133-S
Logic in
Ground
Logic out
ON PTM PTT ON
OFF
SpeechLine
IS microphone series
MAT 153-S
MEB 114-S