Printed Circuit Board) Exchange; Adjustment Volume Location; Test Point Location - Panasonic TH-50PX20U-P Service Manual

High definition plasma television
Hide thumbs Also See for TH-50PX20U-P:
Table of Contents

Advertisement

TH-50PX20U-P
10.3. P.C.B. (Printed Circuit Board) exchange
10.3.1. Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
10.3.2. Quick adjustment after P.C.B. exchange
P.C.B.
P Board
SC Board
SS Board
D, DG Board
*See the Panel label.

10.4. Adjustment Volume Location

10.5. Test Point Location

Name
Test Point
Vsus
TPVSUS (SS)
Vda
TPVDA (SS)
Vad
TPVAD (SC)
Vbk
TPVBK
Vset
TPVSET (SC)
Vscn
TPVSCN (SC)
Ve
TPVE (SS)
White blance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
Voltage
Volume
Vsus* ± 1V
VR641 (P)
75V ± 1V
VR665 (P)
-85V ± 1V
R6477 (SC)
140V ± 1V
R6670 (SC)
220V ± 6V
Vad + 118 ± 2V
---
Ve* ± 1V
R6770 (SS)
26
Remarks
---

Advertisement

Table of Contents
loading

Table of Contents