AudioCodes MP-1 Series Installation Manual

AudioCodes MP-1 Series Installation Manual

Fast track
Hide thumbs Also See for MP-1 Series:
Table of Contents

Advertisement

Quick Links

MP-1xx Fast Track Installation Guide
MGCP, MEGACO, H.323 & SIP
Version 4.21
Document #: LTRT-61402

Advertisement

Table of Contents
loading

Summary of Contents for AudioCodes MP-1 Series

  • Page 1 MP-1xx Fast Track Installation Guide MGCP, MEGACO, H.323 & SIP Version 4.21 Document #: LTRT-61402...
  • Page 2 Trademarks AC logo, Ardito, AudioCoded, AudioCodes, AudioCodes logo, IPmedia, Mediant, MediaPack, MP-MLQ, NetCoder, Stretto, TrunkPack, VoicePacketizer and VoIPerfect, are trademarks or registered trademarks of AudioCodes Limited. All other products or trademarks are property of their respective owners. Customer Support Customer technical support and service are provided by AudioCodes’ Distributors, Partners, and Resellers from whom the product was purchased.
  • Page 3 (including amendments A1: 1998, A2: 1998, A14: 2000) EN61000-3-3: 1995 EN60950: 1992 + Amendments 1, 2, 3 & 4 for MP-124/FXS EN60950: 2000 for MP-1xx/FXS Manufacturer’s Name: AudioCodes Ltd. Manufacturer’s Address: 4 HaHoresh Street, Yehud 56470, Israel. Type of Equipment: Analog VoIP Gateway.
  • Page 4 Standards to which Conformity is Declared: EN55022: 1998, EN55024: 1998 EN61000-3-2: 1995 (including Amendments) EN61000-3-3: 1995 TBR-21: 1998 Manufacturer’s Name: AudioCodes Ltd. Manufacturer’s Address: 4 HaHoresh Street, Yehud 56470, Israel. Type of Equipment: Analog VoIP Gateway. Model Numbers: MP-104 FXO, MP-108 FXO.
  • Page 5 MP-1xx FXO Note The MP-1xx FXO Output Tones and DTMF level should not exceed -9 dBm (AudioCodes setting #23) in order to comply with FCC 68, TIA/EIA/IS-968 and TBR-21. The maximum allowed gain between any 2 ports connected to the PSTN should be set to 0 dB in order to comply...
  • Page 6: Table Of Contents

    MP-1xx Table of Contents Quick Setup for the MP-1xx ..................8 Installing the MP-1xx ....................9 2.1 Unpacking............................9 2.1.1 Package Contents .......................9 2.2 Mounting the MP-1xx.......................... 9 2.2.1 Mounting the MP-1xx on a Desktop or a Shelf..............9 2.2.2 Mounting the MP-1xx in a 19-inch Rack................10 2.2.2.1 Mounting the MP-10x in a 19-inch Rack ..............
  • Page 7 Fast Track Installation Guide Contents List of Figures Figure 1-1: Required Steps to Install the MP-1xx ....................8 Figure 2-1: Desktop or Shelf Mounting ......................10 Figure 2-2: MP-10x with Brackets for Rack Installation ................... 11 Figure 2-3: MP-124 with Brackets for Rack Installation................... 11 Figure 2-4: MP-10x Wall Mount ........................
  • Page 8: Quick Setup For The Mp-1Xx

    MP-1xx Quick Setup for the MP-1xx This guide provides information on how to install the MP-1xx for the first time. Prior knowledge of IP networks is required. The basic configuration procedures, outlined in Figure 1-1, are used to set up, initialize and configure the device.
  • Page 9: Installing The Mp-1Xx

    2 short equal-length brackets and bracket-to-device screws for MP-124 19-inch rack installation Mounting the MP-1xx AudioCodes’ MP-1xx can be mounted on a desktop / shelf, in a standard 19-inch rack, or on a wall (only MP-10x). Refer to Section on page for cabling the MP-1xx.
  • Page 10: Mounting The Mp-1Xx In A 19-Inch Rack

    MP-1xx (FXS), MP-104 (FXS/FXO) and MP-108 (FXS/FXO) are similar except for the number of channels and their corresponding LEDs. Figure 2-1: Desktop or Shelf Mounting Mounting the MP-1xx in a 19-inch Rack 2.2.2 Rack Mount Safety Instructions (UL) When mounting the chassis on a rack, be sure to implement the following Safety instructions: •...
  • Page 11: Mounting The Mp-124 In A 19-Inch Rack

    Fast Track Installation Guide 2. Installing the MP-1xx holes with the rack frame holes, and use 4 standard rack screws (not supplied) to secure the brackets to the rack frame, and cable it as in Section 2.3. Figure 2-2: MP-10x with Brackets for Rack Installation 2.2.2.2 Mounting the MP-124 in a 19-inch Rack Refer to Figure...
  • Page 12: Cabling The Mp-1Xx

    MP-1xx Figure 2-4: MP-10x Wall Mount Cabling the MP-1xx Refer to Table 2-1 on page for the cabling procedure for the MP-1xx. 2.3.1 MP-1xx Rear Panel Connectors Note 1: MP-10x (FXS/FXO) Media Gateways feature identical rear panel connectors and LEDs, located slightly differently from one device to the next.
  • Page 13: Cables And Cabling Procedure

    Fast Track Installation Guide 2. Installing the MP-1xx Figure 2-6: MP-124 (FXS) Rear Panel Connectors Power Supply 50-pin Telco for 1 to 24 Two 10/100 Base-T Socket Analog Lines RJ-45 Ports Grounding Screw LED Indicators 9 pin RS-232 Status Port 2.3.2 Cables and Cabling Procedure Cable your MP-1xx according to each section of Table...
  • Page 14: Figure 2-7: Rj-45 Ethernet Connector Pinouts

    MP-1xx Figure 2-7: RJ-45 Ethernet Connector Pinouts RJ-45 Connector and Pinout 1 2 3 4 5 6 7 8 1 - Tx+ 4, 5, 7, 8 2 - Tx- 3 - Rx+ connected 6 - Rx- Figure 2-8: RJ-11 Phone Connector Pinout RJ-11 Connector and Pinout 1 2 3 4 Not connected...
  • Page 15: Installing The Life Line

    Fast Track Installation Guide 2. Installing the MP-1xx Table 2-2: Pin Allocation in the 50-pin Telco Connector Phone Channel Connector Pins Phone Channel Connector Pins 1/26 13/38 2/27 14/39 3/28 15/40 4/29 16/41 5/30 17/42 6/31 18/43 7/32 19/44 8/33 20/45 9/34 21/46...
  • Page 16: Figure 2-12: Mp-104/Fxs Life Line Setup

    MP-1xx To install the Life Line take these 3 steps: Connect the Life Line Splitter to port number 4 (on the MP-104 FXS or MP-108 FXS) or to port number 2 (on the MP-102 FXS). Connect the Life Line phone to Port A on the Life Line Splitter. Connect an analog PSTN line to Port B on the Life Line Splitter.
  • Page 17: Initializing The Mp-1Xx

    Fast Track Installation Guide 3. Initializing the MP-1xx Initializing the MP-1xx AudioCodes’ MP-1xx application software already resides in the device’s flash memory when it is supplied (with factory default parameters). MP-1xx devices also include an Embedded (integrally stored) Web Server.
  • Page 18: Accessing The Mp-1Xx Embedded Web Server

    MP-1xx • Use an Ethernet cross-over cable to directly connect the network card on your computer to the RJ-45 jack on the MP-1xx. • Use a standard Ethernet cable to connect the network card on your computer to a port on a network hub/switch. Use a second standard Ethernet cable to connect the MP-1xx to another port on the same network hub/switch.
  • Page 19: Restoring Your Pc's Ip Address / Subnet Mask

    Password. If the Embedded Web Server is unavailable (for example, if you’ve lost your User Name and Password), use AudioCodes’ BootP/TFTP configuration utility to access the device, “reflash” the load and reset the Password (refer to the MP-1xx User’s Manuals for detailed information on using a BootP/TFTP server to access the device).
  • Page 20: Provisioning H.323 Parameters

    MP-1xx Select the control protocol type: MGCP or MEGACO, under the section ‘Control Protocol Configuration’. In the ‘Call Agent IP’ box, enter the Call Agent IP address if your enterprise’s network doesn’t feature a DNS server that automatically defines the Call Agent’s IP address.
  • Page 21 Fast Track Installation Guide 3. Initializing the MP-1xx If the MP-1xx is behind a router with NAT enabled, take the following procedures: • Determine the “public” IP address assigned to the router (by using, for instance, router Web management). This “public IP address” is used to configure the MP-1xx Static NAT IP address.
  • Page 22: Figure 3-4: Example Of Connecting Two Mp-108 Devices

    MP-1xx Click the RESET button and click OK in the prompt; The MP-1xx applies the changes and restarts. This takes approximately 60 seconds to complete. When the MP-1xx has finished restarting, the Ready and LAN LEDs on the front panel are lit green. You are now ready to start using the VoIP Gateway.
  • Page 23: Provisioning Sip Parameters

    Fast Track Installation Guide 3. Initializing the MP-1xx Provisioning SIP Parameters To provision SIP parameters take these 11 steps: After completing the steps in Sections (pages & 19), the SIP ‘Quick Setup’ screen shown in Figure 3-5 is accessed. Figure 3-5: MP-1xx SIP Quick Setup Screen If the MP-1xx is behind a router with NAT enabled, take the following procedures: •...
  • Page 24 MP-1xx messages are still sent to the physical ‘Proxy IP Address’ but the SIP URI contains the ‘Proxy Name’ instead. Configure ‘Enable Registration’ to ‘Yes’ or ‘No’: ‘No’ = the MP-1xx does not register to a Proxy server/Registrar (default). ‘Yes’ = the MP-1xx registers to a Proxy server/Registrar at power up and every ‘Registration Time’...
  • Page 25: Changing The Mp-1Xx Password

    Fast Track Installation Guide 4. Changing the MP-1xx Password Changing the MP-1xx Password To prevent unauthorized access to the MP-1xx, it is recommended that you change the User Name and Password that is used to access the Embedded Web Server. To change the Password take these 8 steps: Access the MP-1xx Embedded Web Server via a standard Web browser.
  • Page 26: Monitoring The Mp-1Xx

    MP-1xx Monitoring the MP-1xx The MP-1xx provides several ways of monitoring the status of the Gateway. • Monitoring the MP-1xx front panel LEDs (refer to Section below). • Monitoring the MP-1xx rear panel LEDs (refer to Section on page 27). •...
  • Page 27: Mp-1Xx Rear Panel Leds

    Fast Track Installation Guide 5. Monitoring the MP-1xx MP-1xx Rear Panel LEDs The LEDs on the rear panel are located within the RJ-45 socket. Table 5-2 describes the meaning of each state of the LEDs on the rear panel. Table 5-2: Definition of MP-1xx Rear Panel LED Indicators Label Type Color...
  • Page 28: Figure 5-2: Specific Channel Status Details

    MP-1xx Figure 5-2: Specific Channel Status Details MP-1xx Document #: LTRT-61402...
  • Page 29: Upgrading The Mp-1Xx

    Fast Track Installation Guide 6. Upgrading the MP-1xx Upgrading the MP-1xx To upgrade the MP-1xx (load new software or configuration files onto the VoIP Gateway) use the Software Upgrade feature, available through the Embedded Web Server. Note that for each software load (cmp file), there should be a corresponding configuration file (ini file).
  • Page 30: Backing Up The Gateway Configuration

    MP-1xx To upgrade the VoIP Gateway software and to keep your previous configuration, take these 4 steps: Back up the VoIP Gateway configuration (ini file). Follow the procedure described in Section on page Load the new software (cmp file) onto the VoIP Gateway. Follow the procedure described in Section 6.2.1 on page...
  • Page 31: Updating The Software And Configuration Files

    Fast Track Installation Guide 6. Upgrading the MP-1xx Updating the Software and Configuration Files The Software Update screens allow you to upgrade the VoIP Gateway by downloading new software or configuration files to the VoIP Gateway. 6.2.1 Downloading the Software File To download the software file take these 6 steps: Click the Software Upgrade button.
  • Page 32: Figure 6-3: Auxiliary Files Download Screen

    MP-1xx Figure 6-3: Auxiliary Files Download Screen Click the Browse button that is in the box for the type of file you want to download. Navigate to the folder that contains the file you want to download. Click the file and click the Open button; the filename and path of the file appears in the box beside the Browse button.
  • Page 33: Mp-104 Fxo: Ip To Enterprise Pbx Example

    AudioCodes’ MP-104 FXO connected to analog lines. is a SOHO (Small Office, Home Office) in the USA, without a PBX, but with AudioCodes’ MP-104 FXS User connected to the phones. A calling B scenario (Automatic dialing set in the ini File) User off-hooks the phone, hears the enterprise PBX’s dial tone, and dials...
  • Page 34 MP-1xx USA Headquarters : AudioCodes Inc, 2890 Zanker Road, Suite # 200, San Jose, CA 95134. Tel: +1-408-577-0488 - Fax: +1-408-577-0492 International Headquarters : AudioCodes Ltd, 1 Hayarden Street, Airport City, Lod 70151, Israel. Tel: +972-3-976 4000 - Fax: +972-3-976 4040...

This manual is also suitable for:

Mp-102/fxsMp-104/fxsMp-108/fxsMp-124/fxs

Table of Contents