Sensor Specifications - Teledyne OLCT 10 N User Manual

Digital gas detector
Table of Contents

Advertisement

OLCT 10 N
DIGITAL GAS DETECTOR
USER MANUAL
Certification

7.2 Sensor specifications

Measuring
Gas Type
CH
4
0-100% LEL
Methane
H
2
0-100% LEL
Hydrogen
C
H
3
8
0-100% LEL
Propane
C
H
4
10
0-100% LEL
Butane
CO
300
Carbon monoxide
1000
5000
CO
2
0-5% vol.
Carbon dioxide
0-100% vol.
H
S
30
2
Hydrogen sulfide
100
NH
100
3
Ammonia
1000
NO
100
Nitric oxide
300
NO
10
2
Nitrogen dioxide
30
O
(2 years)
2
0-30 Vol.%
Oxygen
O
(5 years)
2
0-30 Vol.%
Oxygen
24
EMC according to EN 50270:2015 (Type 2)
Explosive Atmospheres : (except CO
versions)
II 3 GD
Ex ec dc IIC T4 Gc for LEL versions
Ex tc IIIC T135°C Dc
-20°C<Ta<+55°C
Temp. Range
range
(°C)
(ppm)
-20 to +55
-20 to +55
-20 to +55
-20 to +55
-20 to +50
-40 to +50
-20 to +50
-20 to +40
-20 to +50
-20 to +50
-20 to +50
-40 to +50
O2 and Toxics
2
Average Life
Accuracy
Expectancy
(month)
± 1% LEL
48
(0-70% LEL)
± 1% LEL
48
(0-70% LEL)
± 1% LEL
48
(0-70% LEL)
± 1% LEL
48
(0-70% LEL)
± 3%
36
± 3%
60
± 3%
36
± 5 ppm
24
± 20 ppm
± 3%
36
± 3%
24
0,4 Vol.%
28
(15-22 %)
± 1.5%
60
T50 / T90
(sec)
6/15
15/40
18/32
19/33
13/22
15/30
25/70
20/60
10/30
30/60
6/15
15/25
NPO10NGB