7 Specifications

7.1 Detector

Dimensions
Ingress protection
Enclosure
Cable entries
Type of cable
Power supply
Consumption (under normal
operating conditions @ 24 V)
Status indication during
calibration
Calibration
ATEX certification temperature
Humidity
Storage conditions
NPO10NGB
Revision J.1
118x110x63 mm
IP65
UV-resistant ABS
2 cable glands, M16, outer diameter 4 to 8 mm
Type MPI-22A
12-30V
Electrochemical sensor: 2.5 mA
Catalytic sensor: 50 mA
Infrared sensor: 20 mA
LED red/green
Non-intrusive and automatic (with the special magnetic
calibration cap) or manual calibration (by potentiometer)
Standard gas value set by the detector
Certified for use in ATEX zones between -20°C and +55°C
15 to 90% RH for the electrochemical sensor
0 to 100% RH uncondensed for the catalytic sensor
Electrochemical sensor:
Infrared sensor:
Catalytic sensor:
OLCT 10 N
DIGITAL GAS DETECTOR
USER MANUAL
4 to 20°C
20 to 60% RH
1 bar ± 10%
6 months maximum
4 to 20°C
10 to 60% RH
1 bar ± 10%
6 months maximum
-50 to +70°C
20 – 60% RH
1 bar ± 10%
6 months maximum