Appendix B - Watchdog Timer - DFI-ITOX SR330-L User Manual

Table of Contents

Advertisement

Appendix B - Watchdog Timer

Watchdog Timer
The following parameters are references for setting the time interval
of the Watchdog Timer function. The system will regularly be "cleared"
according to the set time interval. If the system hangs or fails to
function, it will also reset according to the time interval so that your
system will continue to operate.
;================ PROGRAM START ================
SIO_CON_PORT
SIO_DATA
begin:
MOV
DX,SIO_CON_PORT
MOV
AL,87H
OUT
DX,AL
OUT
DX,AL
MOV
DX,SIO_CON_PORT
MOV
AL,2DH
OUT
DX,AL
MOV
DX,SIO_DATA
IN
AL,DX
AND
AL,0FEH
OUT
DX,AL
MOV
DX,SIO_CON_PORT
MOV
AL,07H
OUT
DX,AL
MOV
DX,SIO_DATA
MOV
AL,08H
OUT
DX,AL
MOV
DX,SIO_CON_PORT
MOV
AL,030H
OUT
DX,AL
MOV
DX,SIO_DATA
OR
AL,01H
OUT
DX,AL
EQU
2EH
EQU
2FH
;SUPERIO ENTER CONFIG
;GPIO5 AND POWER CONTROL SIGNALS
MULTI-FUNCTION PIN SELECTION
;BIT 0 PIN77 SELECT (0= WDTO#, 1=
GPIO50)
;SELECT PIN TO WATCH DOG
;LOGIC DEVICE SLELCT
;SELECT DEVICE 8 (WATCH DOG)
;ACTIVATE REGISTER
;0= INACTIVATE, 1=ACTIVATE
Watchdog Timer
B
141

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr330-l20c

Table of Contents