2. Snooze function (comfort function)
•
active in position 1, 2, 4, 6, 10
The dimmer dims from the current dimming value up to the
minimum brightness within the set dimming time and swit-
ches off (activation via double click).
3. Dimming switch-on function
•
applies for position 1, 2, 4, 6, 7, 8, 10
The dimmer switches on with minimum brightness and dims
until one releases the button again, or the maximum bright-
ness has been reached (activation by pressing the button for
longer, > 1 s).
4. Switch-on brightness
•
applies for position 1, 2, 4, 6, 7, 8, 10
•
Switch-on brightness can be set (presetting 100%) (acti-
vation by pressing the button, < 1 s)
Teach in switch-on brightness
Set the desired switch-on brightness via the button at input
A1/A2 in position 1 (or 2, 4, 6, 7, 8, 10 ).
Keep the button pressed (> 10 seconds) until the teach in
is confirmed by a change in the brightness. Afterwards it is
set to the saved switch-on brightness.
5. Minimum brightness
•
applies for position 3, 5
Teach in the minimum brightness
The pre-set minimum brightness is set in such a manner that
most lamps still light up.
Move the rotary switch to 5 (to 3 for compact fluorescent
lamps). The current minimum brightness is approached.
Press the button at Input A1/A2 and dim up or down until
the desired minimum brightness value is reached.
Let go of the button; the brightness value is taken over.
Set the rotary switch back to the desired function.
▻ Reason: if a certain brightness value is exceeded, cer-
tain compact fluorescent lamps / LEDs go out and no
longer ignite.
Carry out settings only with warm compact fluorescent
lamps (e.g., switch on for approx. 5 minutes).
6. 2-push button function using diode module
with double switch or rocker switch
•
input B1 = push button input
•
with switch-on brightness
•
with dimming switch-on function
•
ON button: switch on / dim up
OFF button: switch off / dim down
L
Diode module 9070367
Diodenmodul
7. Staircase time switch function
Setting the time with potentiometer
B1
ON
EIN
OFF
AUS
(1 s – 60 min)
•
Switch-off pre-warning: after expiry of the set time rapid
dimming down to 50% of the switch-in value. After 10 s,
slow dimming down to minimum brightness within 30 s.
•
Long time function 60 mins: activation by pressing the
button for longer (confirmed by change in brightness)
L Pressing the button again during the expiry time restarts
the expiry time (resettable, cannot be prematurely swit-
ched off).
Brightness
Helligkeit
p
1 s– 60 min
10 s
8. Switch function (e.g., for presence and motion
detector)
•
At Input B1: not defined as push button but as switch
•
Use of the diode module possible, up to 3 light settings
can be selected
•
ON switch: slow dimming up; time can be set at potenti-
ometer 2; setpoint value set with function 5
OFF switch: slow dimming down; time can be set at
potentiometer 2 to minimum brightness, afterwards
switch off
Brightness
Helligkeit
p
100 %
x %
min
0 %
Switch
Switch
B1
A1/A2
•
At button A1/A2
– with switch-on brightness (preset 100 %)
– with dimming switch-on function
– with wake-up and snooze function
6. Operation
Light is OFF (with button: input A1/A2)
Switch-on brightness
1 x short button
< 1 s
press
The dimmer starts with the switch-on bright-
ness taught-in (ex-factory 100 %)
1 x long button
> 1 s
Dimming switch-on function
press
The dimmer switches on with minimum
brightness and dims until one releases the
button again, or the maximum brightness has
been reached.
Wake-up function
2 x short button
press
The dimmer switches on with minimum
brightness, then it is dimmed up using the
set dimming time (potentiometer ) until the
taught-in switch-on brightness.
30 s
Time
Zeit
u
Long button push
langer Tastendruck
Time
Zeit
3