Theben theLeda P12 WH Installation Manual
Theben theLeda P12 WH Installation Manual

Theben theLeda P12 WH Installation Manual

Led spotlight with motion detector

Advertisement

Quick Links

LED spotlight with
EN
motion detector
theLeda P12 WH/AL
1020941/1020942
theLeda P24 WH/AL
1020943/1020944
1. Basic safety information
WARNING
Danger of death through electric shock or fire!
Installation should only be carried out by a
¾
¾
qualified electrician!
!
Only intended for installation out of arm's reach.
!
High temperature! Do not touch the
metal parts of the device.
!
First, connect the device, then adjust the settings at the
potentiometer.
L The LED spotlight with motion detector (PIR) conforms to
EN 60598-1 and EN 60669-2-1 if correctly installed
2. Proper use
For entrances, single-family houses, building front, hotel
entrances, medical practices, etc.
For use in normal ambient conditions
LED spotlight is used for lighting, depending on
presence and brightness
L Lamp cannot be replaced.
Replace entire spotlight if defective!
Disposal
Dispose of device in environmentally sound manner
¾
3. Connection
WARNING
Danger of death through electric shock or fire!
Installation should only be carried out by a
¾
¾
qualified electrician!
Disconnect power source!
¾
Ensure device cannot be switched on!
¾
Check absence of voltage!
¾
Earth and bypass
¾
Cover or shield any adjacent live components
¾
Standard options
307150 01
L
N
S
Additional connection options
!
Ensure correct polarity. When ignored, the lamp flashes
permanently.
!
Protect devices in Master/Slave operation with the same
ground fault circuit interrupter.
!
Devices with PIR = Master, devices without PIR = Slave
Connection Master/Master
1
Master
L
N
S
!
The S connection must be conducted through the same
cable as the L and N line.
!
Max. 10 devices switchable as Master/Master
Several detectors can be switched at the same time by con-
necting the S terminal. If one detector detects motion, all LED
spotlight will be switched on.
Connection Master/Slave
L Optional: with Slave devices 1020741 – 1020744
L
N
S
N
L
2
Master
L
N
S
Master
Slave
L
N
S
50 m
10
Master
L
N
S
N
L
S
50 m
50 m
N
L
S
1

Advertisement

Table of Contents
loading

Summary of Contents for Theben theLeda P12 WH

  • Page 1 Standard options 307150 01 LED spotlight with motion detector theLeda P12 WH/AL 1020941/1020942 theLeda P24 WH/AL 1020943/1020944 1. Basic safety information Additional connection options Ensure correct polarity. When ignored, the lamp flashes WARNING permanently. Danger of death through electric shock or fire!
  • Page 2: Installation Instructions

    4. Installation Loosen screw † ¾ Installation instructions WARNING Danger of death through electric shock or fire! Installation should only be carried out by a ¾ ¾ qualified electrician! L Observe the recommended installation height of 1.8 m–2.5 m! 12 m Loosen catch mechanisms with a screwdriver and remove †...
  • Page 3 Mount the spacer (optional) Place and engage the LED spotlight on the base † † ¾ ¾ Tighten screw † ¾ Remove protective film † ¾ Feed cable through the seal of the base † ¾ Tighten screws † ¾ Ø...
  • Page 4 5. Description Function mode (MODE) Cover 10 % Stand-by night break auto 60 % MODE LED spotlight Turn the potentiometer to „auto“; the LED spotlight swit- † ¾ ches on when there is motion in the dark Turn the potentiometer to „night break“; the LED spotlight †...
  • Page 5: Walking Test

    theLeda P24 8. Walking test The walking test is used to test the detection area and to L 22° swivelling, without spacer restrict it if necessary. 30° swivelling, with mounted spacer Set the time potentiometer (TIME) to „test“. † ¾ 35°...
  • Page 6 Night switch-off „night break“ Twilight switch function on (e.g. 30 %) Setting: Setting: 10 % 10 % Stand-by Stand-by night night 30 s 30 s break break 10 s 10 s auto auto test test 60 % 60 % MODE TIME MODE TIME...
  • Page 7 Permanent on with night switch-off Motion detector without brightness measurement + night switch-off Setting: Setting: 10 % Stand-by night 30 s break 10 % 10 s Stand-by night 30 s break auto test 60 % 10 s MODE TIME auto test 60 % MODE...
  • Page 8: Technical Data

    10. Settings with remote control Settings using theSenda S (9070911) You can also enter the settings with remote controls the- Senda P and theSenda S. L If a new function/parameter is set, the detector flashes 3 x for confirmation. Settings using theSenda P (9070910) The following parameters or functions can be set with theSenda P: D mode...
  • Page 9 12. Contact Theben AG Hohenbergstr. 32 72401 Haigerloch GERMANY Phone +49 7474 692-0 Fax +49 7474 692-150 Hotline Phone +49 7474 692-369 hotline@theben.de Addresses, telephone numbers, etc. www.theben.de...

Table of Contents