MODEL P1261P
PORTABLE TWO CIRCUIT OUTDOOR
TIMER WITH GROUND FAULT PROTECTION.
TOTAL LOAD NOT TO EXCEED: 15A. RESISTIVE, 1800W
(15A.) TUNGSTEN, 1 HP (15 FLA, 90 LRA) - 120 VOLT 60 HZ.
Suitable for Pool/Spa Equipment Control
This portable timer is designed for CONTROLLING the
connected equipment only. Unplug timer before servicing
the unit or the equipment it controls. THIS DEVICE IS NOT
TO BE USED AS A POWER DISCONNECT! For maximum
protection against electrical shock hazard, perform test
procedure on GFCI at least once a month. If used to
control pool/spa equipment install at least 5 feet from inside
edge of pool/spa
The GFCI should be checked every month to make sure it is
operating properly. It is recommended that a permanent record
of the monthly safety check is maintained.
1. Push TEST button. RESET button should pop out from
inner surface. This should result in power being OFF at
the outlets. Verify by plugging test lamp into either outlet. Be
sure the timer is in the ON position.
2. If the GFCI tests okay, restore power by pushing the RESET
button back in. THE RESET BUTTON MUST BE PUSHED
FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND
REMAINS DEPRESSED AFTER PRESSURE HAS BEEN
REMOVED.
DANGER IF RESET BUTTON DOES NOT POP OUT, IF
TEST LAMP REMAINS LIT WHEN RESET BUTTON DOES
POP OUT, OR IF GFCI FAILS TO RESET PROPERLY, DO
NOT USE TIMER! CONTACT A QUALIFIED SERVICE
TECHNICIAN!
TIMER - OPERATING INSTRUCTIONS
1. Insert ON (GREEN) and OFF (RED) trippers into dial at
desired ON and OFF times.
2. Turn dial clockwise and align arrow with Time-of-Day (AM or
PM) in window.
FOR TEMPORARY MANUAL OPERATION
Rotate MANUAL knob counter-clockwise
ON or OFF position. Timer will follow next automatic operation.
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
154--00591
IMPORTANT
.
GFCI TEST PROCEDURE
PRODUCT OF MEXICO
LR3730
to desired

Advertisement

loading

Summary of Contents for Intermatic P1261P

  • Page 1 MODEL P1261P LR3730 PORTABLE TWO CIRCUIT OUTDOOR TIMER WITH GROUND FAULT PROTECTION. TOTAL LOAD NOT TO EXCEED: 15A. RESISTIVE, 1800W (15A.) TUNGSTEN, 1 HP (15 FLA, 90 LRA) - 120 VOLT 60 HZ. Suitable for Pool/Spa Equipment Control IMPORTANT This portable timer is designed for CONTROLLING the connected equipment only.
  • Page 2 IMPORTANT SAFETY INSTRUCTIONS DANGER: To reduce the risk of injury: • Do not permit children to operate the timer or pool/spa unless they are closely supervised at all times. • Test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE the pool or spa! Contact a qualified service technician.
  • Page 3 How to Test the GFCI Congratulations What a GFCI Can–and Cannot–Do It is important to check the GFCI every month to make sure it is You have made the right choice in purchasing a Pool and Spa IT WILL operating properly. Maintain a diary of your monthly test in the Timer that provides not only convenience and energy savings, •...