INSTALLATION
INSTRUCTIONS
DELUXE 36
MANUFACTURED HOME
FIREPLACES
36" Wood Burning Fireplaces
P/N 800,020M REV. N/C 05/2001
MODELS
BM36ST
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and under-
stand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any
circumstances. Any modification or alteration of the fireplace system,
including but not limited to the fireplace, chimney components and
accessories, may void the warranty, listings and approvals of this system
and could result in an unsafe and potentially dangerous installation.
IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS:
INSTALL THIS FIREPLACE IN A SQUARE AND PLUMB CONDITION,
USING SHIMS AS NECESSARY AT SIDES AND/OR BOTTOM.
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.
RETAIN THESE INSTRUCTIONS
WH Report No. J20027921-231
FOR FUTURE REFERENCE
1
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Advertisement

Table of Contents
loading

Summary of Contents for Intertherm DELUXE 36

  • Page 1 INSTALLATION INSTRUCTIONS DELUXE 36 MANUFACTURED HOME FIREPLACES 36" Wood Burning Fireplaces P/N 800,020M REV. N/C 05/2001 MODELS BM36ST This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and under- stand these instructions before beginning your installation.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 2. Always check your local building codes. The The manufacturer is not responsible for any installation must comply with all local, regional, smoking or related problems that may result state and national codes and regulations. from the lack of adequate combustion air. It is Safety Rules ........
  • Page 3: Precautions

    PRECAUTIONS Note: Illustrations shown reflect “typical” To prevent possible personal injury or fire haz- installations with nominal dimensions and ard, the fireplace and chimney must be en- are for design and framing reference only. closed when installed in or passing through a Note: These fireplace systems are not difficult living area where combustibles or people may Actual installations may vary due to indi-...
  • Page 4: Assembly Outline

    Note: Do not insulate the chimney enclosure Check the operation of the damper. The damper Carefully consider the position of the fireplace cavity with blown or fill type insulation materials. is controlled through the use of a control lever openings with respect to the location of adja- located within the firebox opening at the top cent or nearby stairwells, bath or kitchen ex- Note: Local codes may not require firestopping...
  • Page 5: Preinstallation Notes

    PRE-INSTALLATION NOTES CAUTION: DO NOT BLOCK THE HEAT-CIRCU- 1/2" (13 mm) Clearance To LATING AIR INLET AND OUTLET PORTS ON Both Sides CIRCULATING MODELS. DOING SO MAY RE- The BM36ST is a unique two-sided fireplace and SULT IN A POTENTIAL FIRE HAZARD. requires certain minor variations from the nor- mal framing procedures for both new construc- Hearth...
  • Page 6: Fireplace Specifications

    FIREPLACE SPECIFICATIONS 1 ¹⁄₂" (38 mm) 6" (152 mm) Metal Safety Strip 35" 17 ⁷⁄₈" (889 mm) (454 mm) 1 ¹⁄₂" (38 mm) Figure 7 36" (914 mm) 6 ³⁄₈" (162 mm) 39" (991 mm) Front View 12 ¹⁄₂" 12 ¹⁄₂" (317 mm) (317 mm) Blocking...
  • Page 7: Framing Wall Variations

    FRAMING WALL VARIATIONS FRAMING SPECIFICATIONS As many as six (6) different framed wall con- 2 x 4 Or 4 x 4 Header figurations can be constructed to enclose the BM36ST fireplace. The following illustrations depict these variations of wall enclosures. Sev- eral of these designs may incorporate book shelves, wood storage boxes, etc.
  • Page 8: Combustion Air Kit Installation

    Note: If the fireplace is installed against an inside wall, the Class 0 or Class 1 air duct may be extended into a ventilated attic space at least 18" (457 mm) above the attic floor. Se- Plumb Line cure the duct hood to a vertical post with the Nailing Flange inlet positioned downward.
  • Page 9 Ensure the thimble penetrates the roof opening. Step 4. Note: Chimney sections are con- Note: Assemble one component of chimney at The thimble must extend completely through structed with a unique locking tab design, a time (inner section first, then outer section the ceiling or roof cavity to the outermost plane last) before proceeding with the next complete which ensures an immediate, tight assembly...
  • Page 10 Roof Ridge FTF8-S4 Stabilizer Figure 26 120° Note: Do not apply excessive pressure to any Figure 28 subsequent chimney sections following the Figure 30 stabilizer when installing. Ensure each subse- Step 8. The standard FireCraft Technologies' Step 10. Using a CTD Termination: quent chimney section is securely attached by FTF8 roof flashing assemblies include a storm testing as noted in Step 4.
  • Page 11: Ten Foot Rule Summary

    TEN FOOT RULE SUMMARY 1. Determine total vertical height of the fire- SPECIAL OFFSET INSTRUCTIONS place installation. This dimension is measured from the surface the fireplace sets on to the The minimum chimney height above the roof Chimney 30° Offset through Floor or Ceiling point where smoke exits from the termination.
  • Page 12: Vertical Elevation Chart

    A ¹⁄₈" diameter hole must be drilled in the OFFSET CALCULATIONS chimney joint using a ¹⁄₈" diameter drill. Hole should be drilled in center of joint overlap ( see Step 1. Use Offset Chart to determine amount Figure 37 ). Be sure to drill only through the of horizontal offset (A) and height (B) for Return Elbow...
  • Page 13: Offset Elevation Chart

    FTF8 OFFSET ELEVATION CHART FTF8-ES30 Number of Offset Height Offset/Return FTF8-S4 Chimney Sections Offset Height (Inches) (Inches) Elbow Set Stabilizer 12" 18" 36" 48" (mm) (mm) 15 ³⁄₄ 24 ¹⁄₂ 29 ³⁄₄ 14 ¹⁄₄ 33 ¹⁄₂ 17 ¹⁄₄ 38 ¹⁄₂ 20 ¹⁄₄...
  • Page 14: Installing Offsets

    INSTALLING OFFSETS If additional length of duct is necessary, pur- chase locally available Class 0 or Class 1 ducting. The duct may extend up to 50' (15.2 m) in any First, review the Offset Elevation Chart and see direction. Figure 38 for reference. Outside combustion air may be run upwards or Step 1.
  • Page 15: Gas Line Connection

    Gas Line Connection If removal is attempted from the outer wrapper, Use noncombustible caulking material only on side refractory damage may occur. With a me- fireplace facing to seal. Also, the outside air Install only a ¹⁄₂" black iron pipe through fire- dium-sized hammer, lightly tap the surface of inlet duct should be wrapped with noncom- the indentation.
  • Page 16 The hearth extension must extend beyond If the fireplace is installed on a combustible At times it is important to know what combina- both of the BM36ST fireplace side openings. floor, use the metal safety strips (provided) tion of materials are acceptable for use as on the floor extending half under the fire- Use a hearth extension constructed of a du- hearth extensions.
  • Page 17: Finish Requirements

    A ³⁄₄" marble slab set in ¹⁄₂" mortar covers the FINISH TO YOUR TASTE brick, “R” for the marble and mortar becomes: There are a wide variety of “finished looks” for = 0.09 x ³⁄₄" = .068 “R” = r x T these fireplaces, from formal wall decor with = 0.20 x ¹⁄₂"...
  • Page 18 INSTALLATION COMPONENTS Offset/ Return Round Termination 63L42 FTF8-CTD Package (30°) 63L22 FTF8-ES30 Stabilizer 63L25 FTF8-S4 Firestop/Thimble 19M20 F8-FSTAE-2 Storm Collar 63L59 Chimney Pipe Kits 19M18 F8-MHPK3 Locking Band 63L60 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 19 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 20 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2001 by LHP 4325 Artesia Avenue •...