Sinclair SCV-900EB Installation & User Manual

Sinclair SCV-900EB Installation & User Manual

Air-cooled modular chiller unit
Hide thumbs Also See for SCV-900EB:

Advertisement

Quick Links

MODULAR CHILLER UNIT
INSTALLATION & USER MANUAL
AIR-COOLED
SCV-750EB
SCV-900EB
SCV-1400EB
SCV-1800EB
AIR CONDITIONING

Advertisement

Table of Contents
loading

Summary of Contents for Sinclair SCV-900EB

  • Page 1 AIR-COOLED MODULAR CHILLER UNIT INSTALLATION & USER MANUAL SCV-750EB SCV-900EB SCV-1400EB SCV-1800EB AIR CONDITIONING...
  • Page 3 “Original instructions”...
  • Page 4: Table Of Contents

    CONTENTS ACCESSORIES INTRODUCTION use conditions of the unit 2 SAFETY CONSIDERATION BEFORE INSTALLATION Handling of the unit 4 IMPORTANT INFORMATION ON REFRIGERANT 5 SELECTION OF INSTALLATION SITE PRECAUTIONS ON INSTALLATION Outline dimensional drawing Requirements of arrangement space of the unit Installation foundation Installation of damping devices Installation of device to prevent snow build-up and strong breeze...
  • Page 5 11 MAINTENANCE AND UPKEEP 11.1 Failure information and code 11.2 Data display of wired controller 11.3 Care and maintenance 11.4 Removing scale 11.5 Winter shutdown 11.6 Replacing parts 11.7 First startup after shutdown 11.8 Refrigeration system 11.9 Disassembling compressor 11.10 Auxiliary electric heater 11.11 System antifreezing...
  • Page 6: Accessories

    SCV-750EB&SCV-1400EB COOLING HEATING Outlet water temperature (℃) Outlet water temperature (℃) Fig. 1-1-1 Cooling operating range Fig. 1-1-2 Heating operating range SCV-900EB&SCV-1800EB SCV-900EB&SCV-1800EB COOLING HEATING Outlet water temperature (℃) Outlet water temperature (℃) Fig. 1-2-1 Cooling operating range Fig. 1-2-2 Heating operating range Low leaving water temperature mode can be set by wired controller, please refer to the Operation Manual(select “LOW...
  • Page 7: Safety Consideration

    2. SAFETY CONSIDERATION The precautions listed here are divided into the following types.They are quite important, so be sure to follow them carefully. Meanings of DANGER, WARNING, CAUTION and NOTE symbols. INFORMATION Read these instructions carefully before installation. Keep this manual in a handy for future peference. Improper installation of equipment or accessories may result in electric shock, short-circuit, leakage, fire or other damage to the equipment.
  • Page 8 WARNING Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants. Tear apart and throw away plastic packaging bags so that children will not play with them.Children that playing with plastic bags face danger of death by suffocation.
  • Page 9: Before Installation

    Do not install the unit in the following places: - Where there is mist of mineral oil, oil spray or vapors. Plastic parts may deteriorate, and cause possible loose or water to leak. - Where corrosive gases (such as sulphurous acid gas) are produced. Where corrosion of copper pipes or soldered parts may cause refrigerant leakage.
  • Page 10: Important Information On Refrigerant

    Add the refrigerant Amount of factory-charged refrigerant and tonnes CO Equivalent is Table 4-1 Model Refrigerant(kg) Tonnes CO equivalent SCV-750EB 6.08 SCV-900EB 10.80 SCV-1400EB 15.5 10.46 SCV-1800EB 32.0 21.60 5 SELECTION OF INSTALLATION SITE 1) Units can be installed on the ground or proper place on a roof, provided that sufficient ventilation can be guaranteed.
  • Page 11: Precautions On Installation

    6 PRECAUTIONS ON INSTALLATION 6.1 Outline dimensional drawing Front view Left view Top view Fig. 6-1 Outline dimensional...
  • Page 12 Front view Left view Top view Fig. 6-2 Outline dimensional of SCV-1800EB Table 6-1 SCV-1800EB Model SCV-750EB SCV-900EB SCV-1400EB 2752 2000 2220 2220 2220 1135 1135 2413 1770 2315 2300 NOTE After installing the spring damper, the total height of the unit will increase by 135mm approximately.
  • Page 13: Requirements Of Arrangement Space Of The Unit

    6.2 Requirements of arrangement space of the unit 1) To ensure adequate airflow entering the condenser, the influence of descending airflow caused by the high-rise buildings around upon the unit should be taken into account when installing the unit. 2) If the unit is installed where the flowing speed of air is high, such as on the exposed roof, the measures including sunk fence and Persian blinds can be taken, to prevent the turbulent flow from disturbing the air entering the unit.
  • Page 14: Installation Foundation

    Fig. 6-7 considered for the base height. dimension SCV-900EB&SCV-1400EB 3) Either steel or concrete bases may be suitable. 4) A typical concrete base design is shown in Fig. 6-5. A typical concrete specification is 1 part cement, 2 parts sand and 4 parts...
  • Page 15: Installation Of Device To Prevent Snow Build-Up And Strong Breeze

    6.5.1 Measures used to prevent problems caused by snow Anchor bolt 1) Measures to prevent build-up of snow The base height should be as least the same as the predicted Ferrol snow depth in the local area. Damping device Outdoor unit Fig.
  • Page 16: Connection Drawing Of Pipeline System

    7 CONNECTION DRAWING OF PIPELINE SYSTEM This is the water system of standard module. Expansion tank Water replenishing Dirt discharge valve Y-type filter, unit requiring≥ 40 meshes unit Terminal unit Drain valve Two-way valve Auxiliary electric heater Three-way valve Symbol explanation Stop valve Pressure gauge Flexible joint...
  • Page 17 Fig. 8-1 Main parts of SCV-750EB Fig. 8-2 Main parts of SCV-900EB (Picture just use to show the key component relative position) (Picture just use to show the key component relative position) Fig. 8-3 Main parts of SCV-1400EB (Picture just use to show the key component relative position)
  • Page 18: Opening The Uint

    Cover 3 Cover 6 Cover 5 Cover 4 Fig. 8-7 Doors of SCV-900EB&SCV-1400EB Cover 1/2/3 give access to the compartment of water pipes and water side heat exchanger. Cover 4 give access to the electrical parts. Cover 5/6 give access to the hydraulic compartment.
  • Page 19 Door 1 Door 2 Door 3 Door 4 Door 5 Door 6 Door 7 Door 8 Door 9 Door 10 Fig. 8-8 Doors of SCV-1800EB Door 1/2/3/9/10 give access to the compartment of water pipes and water side heat exchanger. Door 4/5 give access to the hydraulic compartment.
  • Page 20: Outdoor Unit Pcbs

    8.3 Outdoor unit PCBs 8.3.1 MAIN PCB 1) Label descriptions are given in Table 8-2 33 34 38 39 13 12 Fig. 8-9 Main board of SCV-750EB and SCV-1400EB Table 8-2 Detail information CN32:Main board power supply. CN99:slave board power supply. CN68:Pump(220-240V control power supply ) 1)After receiving start-up instruction, the pump will be started up instantly, and will maintain start-up state always in the process of operation.
  • Page 21 Detail information CN65:Program burn in port(USB). CN28:Three-phase protector output switch.(Protection code E8) CN22:Outdoor units communication and wired controller conmunication port CN46:The power supply port of the wired controller (DC12V) CN26: Compressor inverter module and Fan inverter module communication ports CN300:Program burn in port(WizPro200RS programming device). CN33:Conmunicate with slave board CN41:System low pressure sensor CN40:System high pressure sensor...
  • Page 22 14 15 Fig. 8-10 Slave board of SCV-750EB and SCV-1400EB Detail information CN140:Power supply,220-240VAC input CN115:W-HEAT,Electric heater of water flow switch CN125:Three-way valve(hot-water valve,reserve) CN123:Pump(220-240V control power supply ) 1)After receiving start-up instruction, the pump will be started up instantly, and will maintain start-up state always in the process of operation.
  • Page 23 8.3.2MAIN PCB 1) Label descriptions are given in Table 8-3 46 47 Fig. 8-11 Main PCB of SCV-900EB and SCV-1800EB Table 8-3 Detail information CN30:Input of three-phase four-wire power supply (fault code E1) Input of transformer, 220-240V AC current. (only valid for the main unit) Three phases A, B and C of power supply should exist 120° among them.
  • Page 24 Detail information CN33:COMP-STATE,connect with an ac light to indicate the state of the compressor Attention: the control port value of the comp-state actually detected is ON/OFF but not 220-240V control power supply,so special attention should be paid when installing the light. CN2:HEAT1.Pipeline Auxiliary Heater Attention: the control port value of the HEAT1 actually detected is ON/OFF but not 220-240V control power supply,...
  • Page 25: Electric Wiring

    S5-3: Normal control, valid for S5-3 OFF(factory default). Remote control, valid for S5-3 ON. CN7:TEMP-SW,Target water temperature switching port.ENC2:POWERDIP switch for capacity selection. (SCV-900EB defaults 2,SCV-1800EB defaults 6) CN74:The power supply port of the HMI .(DC9V) ENC4:NET_ADDRESS DIP switch 0-F of outdoor unit network address is enabled, which represent address 0-15.
  • Page 26 DIP switch for capacity selection 0111 (SCV-1400EB defaults 0111) Fig. 8-13 Display positions 8.4.3 DIP switch instructions 8.4.2 SCV-900EB and SCV-1800EB DIP switch, buttons and digital display positions of uints. Table 8-5 SCV-900EB and SCV-1800EB DIP switch for capacity selection...
  • Page 27 Manual switch Fuse Wiring Model 380-415V/3N~50Hz 100A 16mm X5(<20m) SCV-750EB 380-415V/3N~50Hz 125A 100A 25mm X5(<20m) SCV-900EB 380-415V/3N~50Hz SCV-1400EB 200A 150A 50mm X5(<20m) 380-415V/3N~50Hz SCV-1800EB 250A 70mm X5(<20m) 200A NOTE See the table above for power wire diameter and length when the voltage drop at the power wiring point is within 2%.
  • Page 28 8.4.6 Requirements for power supply wiring Correct Power distribution Manual transformer Lightning switch Fuses arrester Grounding wire Power 380-415V Building 3N~50Hz Uint Grounding 1 Grounding 2 Grounding 3 Wrong Power distribution transformer Manual Lightning arrester switch Fuses Grounding wire Power 380-415V 3N~50Hz Surge...
  • Page 29 SCV-750EB and SCV-1400EB ) As shown in the figure below, For SCV-900EB and SCV-1800EB: the uint communication signal wire is connected to the terminal block XT2 at 5(X), 6(Y) and 7(E), and the wired...
  • Page 30 CN138 at slave board inside the electric controlbox to enable the remote function of “HEAT/COOL”. For SCV-900EB and SCV-1800EB:Shorting the terminal block XT2 at 14 and 23 inside the electric control box to enable the remote function of “HEAT/COOL”.
  • Page 31 8.4.14 Wiring instances If multiple units are connected in cascade, the unit address should be set on the DIP switch ENC1. With 0-F being valid, 0 indicates the master unit and 1-F indicate slave units. CN46 CN46 CN46 Fig. 8-25 Networking communication schematic of main unit and auxiliary unit for SCV-750EB...
  • Page 32 If multiple units are connected in cascade, the unit address should be set on the DIP switch ENC4. With 0-F being valid, 0 indicates the master unit and 1-F indicate slave units. Fig. 8-26 Networking communication schematic of main unit and auxiliary unit for SCV-900EB...
  • Page 33 If multiple units are connected in cascade, the unit address should be set on the DIP switch ENC1. With 0-F being valid, 0 indicates the master unit and 1-F indicate slave units. CN46 CN46 CN46 Fig. 8-27 Networking communication schematic of main unit and auxiliary unit for SCV-1400EB...
  • Page 34 If multiple units are connected in cascade, the unit address should be set on the DIP switch ENC4. With 0-F being valid, 0 indicates the master unit and 1-F indicate slave units. Fig. 8-28 Networking communication schematic of main unit and auxiliary unit for SCV-1800EB...
  • Page 35: Water System Installation

    e) The pipes and their ports must be independently NOTE supported but should not be supported on the unit. f) The pipes and their ports of the heat exchanger should When the power cord is parallel to the signal wire, be easy to disassemble for operation and cleaning, as make sure that they are enclosed in respective well as inspection of port pipes of the evaporator.
  • Page 36 8.5.2 Connection mode of pipe The water inlet and outlet pipes are installed and connected as shown in the following figures. SCV-750EB,SCV-900EB,SCV-1400EB,SCV-1800EB model uses hoop connection. For the specifications of the water pipes and screw thread, see the Table 8-5 below.
  • Page 37 Therefore, the quality of SCV-750EB 15.5 chilled water should be analyzed before being used, 10.2 SCV-900EB such as PH value, conductivity, concentration of chloride SCV-1400EB ion, concentration of sulfide ion, and so on. 15.6 28.5 SCV-1800EB 20.4...
  • Page 38 2) Applicable standard of water quality for the unit Table 8-7 PH value 6.8~8.0 Sulfate <50ppm Total hardness <70ppm Silicon <30ppm Conductivity <200μV/cm(25°C) Iron content <0.3ppm Sulfide ion Sodium ion No requirement Chloride ion <50ppm Calcium ion <50ppm Ammonia ion 8.5.9 Installation of multi-module water system pipeline Multi-module combination installation involves special design of the unit, so relevant explanation is given as follows.
  • Page 39: Strat-Up And Configruation

    1) DIP switch pumps are installed, refer to figure as follow. The choice of DIP switch see Table 8-5 in detail when single or multiple water pumps are installed for SCV-750EBand SCV-900EB and SCV-1400EB andSCV-1800EB. unit unit (1#) unit (0#)
  • Page 40: Test Run And Final Check

    10 TEST RUN AND FINAL CHECK 10.1 Check item table after installation Table 10-1 Checking item Description Units are fixed mounting on level base. Ventilating space for heat exchanger at the air side is meeting for requirement Maintenance space is meeting for requirement. Whether installing site is meet for requirements Noise and vibration is meeting for requirement.
  • Page 41: Maintenance And Upkeep

    In case the unit runs under abnormal condition, failure protection code will display on both control panel and wired controller, and the indicator on the wired controller will flash with 1Hz. The display codes are shown in the following table: Table11-1 SCV-750EB and SCV-900EB and SCV-1400EB and SCV-1800EB No. Code...
  • Page 42 No. Code Content Note 1F4 module A L0 or L1 protection occursfor 3 times in 60 minutes Recovered by power off 2F4 module B L0 or L1 protection occursfor 3 times in 60 minutes Recovered by power off 1F6 A system bus voltage error (PTC) Recovered upon error recovery 2F6 B system bus voltage error (PTC) Recovered upon error recovery...
  • Page 43: Data Display Of Wired Controller

    11.2 Digital display of main board Close attention should be paid to the discharge and suction pressure during the running process. Find out reasons and eliminate the failure if abnormality is The data display area is divided into Up area and Down area, found.
  • Page 44: First Startup After Shutdown

    11.7 First startup after shutdown 11.9 Disassembling compressor The folowing preparations should be made for re-startup of unit Follow the following procedures if compressor needs to be after long-time shutdown: disassembled: 1) Thoroughly check and clean unit. 1) Cut off the power supply of unit. 2) Clean water pipe system.
  • Page 45: Replacement Of Safety Valve

    11.12 Replacement of safety valve Replace the safety valve as follows: 1) Reclaim the refrigerant completely in the system. Doing so requires professional staff and equipment; 2) Note to protect the tank coating. Please avoid damaging to coating from external force or high temperature when removing and installing the safety valve;...
  • Page 46: Information Servicing

    INFORMATION SERVICING 11.13 1) Checks to the area Before working on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minmised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
  • Page 47 b) Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
  • Page 48 Label the system when charging is complete(if not already). Extreme care shall be taken not to overfill the refrigeration system. Before recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning.
  • Page 49: Record Table Of Test Run And Maintenance

    RECORD TABLE OF TEST RUN AND MAINTENANCE Table 11-2 Model: Code labeled on the unit: Customer name and address: Date: 1. Check temperature of chilled water or hot water Inlet ( Outlet ( 2. Check air temperature of air-side heat exchanger: Inlet ( Outlet ( 3.
  • Page 50: Applicable Models And Main Parameters

    12 APPLICABLE MODELS AND MAIN PARAMETERS Table 12-1 Model SCV-750EB SCV-900EB SCV-1400EB SCV-1800EB 164.0 Cooling capacity 70.0 82.0 130.0 180.0 Heating capacity 75.0 90.0 138.0 Standard cooling input 26.8 27.8 50.5 56.0 Cooling rated current 41.2 42.9 77.6 86.4 Standard heating input 23.7...
  • Page 51: Information Requirements

    GWP of the refrigerant (100 years) Standard rating conditions used: Low temperature application Sinclair Corporation, Ltd.16 Great Queen Street Covent Contact details GardenLondonWC2B 5AH (*) If C is not determined by measurement then the default degradation coefficient of chillers shall be 0,9.
  • Page 52 GWP of the refrigerant (100 years) Standard rating conditions used: Low temperature application Sinclair Corporation, Ltd.16 Great Queen StreetCovent Contact details GardenLondonWC2B 5AH (*) If C is not determined by measurement then the default degradation coefficient of chillers shall be 0,9.
  • Page 53 GWP of the refrigerant (100 years) Standard rating conditions used: Low temperature application Sinclair Corporation, Ltd.16 Great Queen StreetCovent Contact details GardenLondonWC2B 5AH (*) If C is not determined by measurement then the default degradation coefficient of chillers shall be 0,9.
  • Page 54 GWP of the refrigerant (100 years) Standard rating conditions used: Low temperature application Sinclair Corporation, Ltd.16 Great Queen StreetCovent Contact details GardenLondonWC2B 5AH (*) If C is not determined by measurement then the default degradation coefficient of chillers shall be 0,9.
  • Page 55 Table 13-5 Information requirements for heat pump space heaters and heat pump combination heaters Model(s): SCV-750EB [yes] Air-to-water heat pump: [yes/no] Water-to-water heat pump: [yes/no] Brine-to-water heat pump: [yes/no] Low-temperature heat pump: [yes/no] Equipped with a supplementary heater: [yes/no] Heat pump combination heater: For low-temperature heat pumps, parameters shall be declared for low-temperature application.
  • Page 56 Table 13-6 Information requirements for heat pump space heaters and heat pump combination heaters Model(s): SCV-900EB [yes] Air-to-water heat pump: [yes/no] Water-to-water heat pump: [yes/no] Brine-to-water heat pump: [yes/no] Low-temperature heat pump: [yes/no] Equipped with a supplementary heater: [yes/no] Heat pump combination heater: For low-temperature heat pumps, parameters shall be declared for low-temperature application.
  • Page 57 Table 13-7 Information requirements for heat pump space heaters and heat pump combination heaters Model(s): SCV-1400EB [yes] Air-to-water heat pump: [yes/no] Water-to-water heat pump: [yes/no] Brine-to-water heat pump: [yes/no] Low-temperature heat pump: [yes/no] Equipped with a supplementary heater: [yes/no] Heat pump combination heater: For low-temperature heat pumps, parameters shall be declared for low-temperature application.
  • Page 58 Table 13-8 Information requirements for heat pump space heaters and heat pump combination heaters Model(s): SCV-1800EB [yes] Air-to-water heat pump: [yes/no] Water-to-water heat pump: [yes/no] Brine-to-water heat pump: [yes/no] Low-temperature heat pump: [yes/no] Equipped with a supplementary heater: [yes/no] Heat pump combination heater: For low-temperature heat pumps, parameters shall be declared for low-temperature application.
  • Page 60 6 Great Queen WC2B 5AH...

This manual is also suitable for:

Scv-750ebScv-1400ebScv-1800eb

Table of Contents