• Use the air direction adjustments within the ranges
shown above.
• The vertical air flow direction is set automatically as
shown, in accordance with the type of operation
selected.
During Cooling/Dry mode : Horizontal flow q
During Heating mode
• During AUTO mode operation, for the first minute after
beginning operation, airflow will be horizontal q ; the
air direction cannot be adjusted during this period.
Right-Left Adjustment
Adjust the Right-Left Louvers.
• Move the Right-Left louvers to adjust air flow in the
direction you prefer.
• Never place fingers or foreign objects inside the outlet ports,
since the internal fan operates at high speed and could cause
personal injury.
• Always use the remote control unit's AIR FLOW DIRECTION
button to adjust the vertical airflow louvers. Attempting to
move them manually could result in improper operation; in
this case, stop operation and restart. The louvers should
begin to operate properly again.
• During use of the Cooling and Dry modes, do not set the Air
Flow Direction Louvers in the range (t to u) for long
periods of time, since water vapor may condense near the
outlet louvers and drops of water may drip from the air
conditioner. During the Cooling and Dry modes, if the Air
Flow Direction Louvers are left in the range (t to u) for
more than 30 minutes, they will automatically return to
position r.
• When used in a room with infants, children, elderly or sick
persons, the air direction and room temperature should be
considered carefully when making settings.
10. TIMER
q ON timer or OFF timer
(1) Press the START/STOP button.
(if the unit is already operating, proceed to step 2).
The indoor unit's OPERATION Indicator Lamp (red)
will light.
• To Cancel the Timer
Use the TIMER button to select "TIMER RESET."
The air conditioner will return to normal operation.
(2) Press the TIMER button to select the OFF timer or ON
timer operation.
Each time the button is pressed the timer function
changes in the following order :
The indoor unit's TIMER Indicator lamp (green) will
light.
• To Change the Timer Setting
Perform steps (2) and (3).
RESET
PROGRAM (OFF
: Downward flow u
Right-Left Louvers
Knob
OFF
ON
ON, OFF
ON)
• To Stop Air Conditioner Operation while the Timer
is Operating
Press the START/STOP button.
(3) Use the SET TEMP/SET TIME button to adjust the
desired OFF time or ON time.
Set the time while the time display is flashing
(the flashing will continue for about five seconds).
+
button : Press to advance the time.
button : Press to reverse the time.
About five seconds later, the entire display will reappear.
• To Change Operating Conditions
If you wish to change operating conditions (Mode, Fan
Speed, Thermostat Setting), after making the timer
setting wait until the entire display reappears, then
press the appropriate buttons to change the operating
condition desired.
About the Program timer
• The PROGRAM timer allows you to integrate OFF
timer and ON timer operations in a single sequence.
The sequence can involve one transition from OFF
timer to ON timer, or from ON timer to OFF timer,
within a twenty-four hour period.
• The first timer function to operate will be the one set
nearest to the current time. The order of operation is
indicated by the arrow in the Remote Control Unit's
display (OFF
ON, or OFF
• One example of Program timer use might be to have
the air conditioner automatically stop (OFF timer) after
you go to sleep, then start (ON timer) automatically in
the morning before you arise.
w Program timer
(1) Press the START/STOP button.
(if the unit is already operating, proceed to step 2).
The indoor unit's OPERATION Indicator Lamp (red)
will light.
• To Cancel the Timer
Use the TIMER button to select "TIMER RESET."
The air conditioner will return to normal operation.
(2) Set the desired times for OFF timer and ON timer.
See the section "To Use the ON Timer or OFF Timer"
to set the desired mode and times.
About three seconds later, the entire display will
reappear.
The indoor unit's TIMER Indicator Lamp (green) will
light.
• To Change the Timer Setting
1. Follow the instructions given in the section "To Use
the ON Timer or OFF Timer" to select the timer
setting you wish to change.
2. Press the TIMER button to select either OFF
or OFF
ON.
(3) Press the TIMER button to select the PROGRAM
timer operation (either OFF
will display).
The display will alternately show "OFF timer" and
"ON timer", then change to show the time setting
for the operation to occur first.
The PROGRAM timer will begin operation. (If the ON
timer has been selected to operate first, the unit will
stop operating at this point).
About five seconds later, the entire display will reappear.
• To Stop Air Conditioner Operation while the Timer
is Operating
Press the START/STOP button.