WARNING:
Serious injury may result if the cabinet is improperly han-
dled or proper safety conditions are not met. Check the
cabinet sides, top, front door, and rear panel for damage. If
the cabinet is damaged, do the following:
a. Enter the location and extent of the damage on the LARS report.
b. Notify the customer and your unit manager.
c. Stop unpacking until the customer gives you permission to con-
tinue.
1.
Using an adjustable wrench, remove the four bolts and shipping
brackets that hold the cabinet leveler feet to the pallet (Figure 2-3).
2.
The leveler feet are lowered to the pallet surface for shipment. Using
the adjustable wrench, raise the feet to the upmost position before re-
moving the system from the pallet (see Section 2.5).
3.
Attach the ramps by fitting the prongs into the holes on the front of
the pallet. Place the ramps so that the runners are on the inside. Align
the arrows on the ramps and pallet (see Figure 2-3).
4.
With two people working together (one in front and one in back),
slowly roll the cabinet off the pallet down the ramps. Move the cabinet
into position. This should be done on a firm level floor. To avoid static
electricity which can cause system problems, do not place the system
on a carpet.
NOTE: Make sure the space under the cabinet is clear of any debris or ex-
traneous materials.
Installing the System Cabinet 2-9