AV-25PX
PURITY, CONVERGENCE ADJUSTMENT
PURITY ADJUSTMENT
1. Demagnetize CRT with the demagnetizer.
2. Loosen the retainer screw of the deflection yoke.
3. Remove the wedges.
4. Input a green raster signal from the signal generator, and turn
the screen to green raster.
5. Move the deflection yoke backward.
6. Bring the long lug of the purity magnets on the short lug and
position them horizontally. (Fig.2)
7. Adjust the gap between two lugs so that the GREEN RASTER
will come into the center of the screen. (Fig.3)
8. Move the deflection yoke forward, and fix the position of the
deflection yoke so that the whole screen will become green.
9. Insert the wedge to the top side of the deflection yoke so that it
will not move.
10. Input a crosshatch signal.
11. Verify that the screen is horizontal.
12. Input red and blue raster signals, and make sure that purity is
properly adjusted.
30
WEDGE
CRT
P/C MAGNETS
P : PURITY MAGNET
4 : 4 POLES (convergence magnets)
6 : 6 POLES (convergence magnets)
Short lug
Bring the long lug over the short lug
and position them horizontally.
(FRONT VIEW)
No.51752
DYNAMIC CONVERGENCE ADJUSTMENT
PURITY MAGNET(P)
4 6
CRT SOCKET PWB
P / C MAGNETS
DEF. YOKE
Fig.1
PURITY MAGNETS
Long lug
Fig.2
GREEN RASTER
CENTER
Fig.3