Measuring
Item
instrument
AUDIO CIRCUIT ADJUSTMENT
Do not adjust 3.AUDIO(1. ERROR LIMIT, 2. A2 ID THR, 3. BASS, 4. TREBLE) of the SERVICE MENU as it requires no adjustment.
3. AUDIO [Do not adjust]
Setting item
1. ERROR LIMIT
2. A2 ID THR
3. BASS
4. TREBLE
Test point
Adjustment part
Variable range
000H ~ FF0H
00H ~ FFH
-17 ~ +17
-17 ~ +17
No. 51752
Description
At first the adjustment in 50Hz-REGULAR mode should be
done, then the data for the other aspect mode is corrected in
the respective value at the same time. And confirm the
deflection adjustment initial setting value in 60Hz( NTSC Video
mode ) REGULAR mode. If the adjustment in 50Hz each aspect
mode has been done and stored, the data for the same aspect
modes in 60Hz is corrected in the respective value. Only the
data for the other aspect mode in 60Hz is corrected for itself.
AV-25PX
fixed value
100H
14H
+0
+0
29