Download Print this page
Lennox ML180DFE Series User's Information Manual

Lennox ML180DFE Series User's Information Manual

Hide thumbs Also See for ML180DFE Series:

Advertisement

Quick Links

2017 Lennox Industries Inc.
©
Dallas, Texas, USA
506735-01
10/2017
Supersedes 05/2011
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WARNING
Improper
installation,
service or maintenance can cause property damage,
personal injury or loss of life. Installation and service
must
be performed by a licensed professional
HVAC installer or equivalent, service agency, or the
gas supplier.
WARNING
FIRE OR EXPLOSION HAZARD.
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
USER'S INFORMATION
GAS FURNACE
adjustment,
alteration,
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
MANUAL
ML180DFE
SERIES

Advertisement

loading

Summary of Contents for Lennox ML180DFE Series

  • Page 1 USER’S INFORMATION MANUAL 2017 Lennox Industries Inc. © ML180DFE Dallas, Texas, USA SERIES 506735-01 10/2017 Supersedes 05/2011 GAS FURNACE WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service...
  • Page 2 ML180DFE Parts Identification TOP CAP BLOWER MOTOR PRESSURE SWITCH ASSEMBLY INTEGRATED CONTROL COMBUSTION AIR INDUCER GAS VALVE AND BURNERS MANIFOLD FIGURE 1 NOTE - This manual is the property of the homeowner CAUTION and must be left with the equipment user. Before attempting to perform any service or Notice to Homeowner maintenance, turn the electrical power to unit OFF...
  • Page 3 These products can cause furnace corrosion. fireplaces) has the potential to produce carbon monoxide gas. Because of this, Lennox recommends the use of 4 - DO NOT draw return air from a room where this a carbon monoxide detector in your home, even if furnace, or any other gas appliance (ie., a water...
  • Page 4 Start-Up & Operation Information MANIFOLD MANIFOLD PRESSURE PRESSURE WARNING ADJUSTMENT OUTLET SCREW PORT If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or death. INLET BEFORE LIGHTING smell all around the appliance area PRESSURE PORT for gas.
  • Page 5 ELECTRICAL SHOCK, FIRE, Service Reminder OR EXPLOSION HAZARD. Call your Lennox service technician if the unit will not op- Failure to follow safety warnings exactly could erate. Before calling, always check the following to be result in dangerous operation, serious injury, death sure service is required.
  • Page 6 4 - Check the cleanliness of filters and change if If you discover any of the following, shut down your necessary (monthly). unit, and contact a Lennox dealer for an inspection by a licensed professional service technician (or equiv- 5 - Check the condition and cleanliness of burners and alent).
  • Page 7 Repair Parts List The following repair parts are available through Lennox dealers. When ordering parts, include the complete furnace model number listed on the CSA International nameplate -- Example: ML180DF045E36B-01. All service must be done by a licensed professional installer (or equivalent), a service agency, or the gas supplier.