General Information; Installation Instructions; Operation Instructions - APW Wyott XTRM-1 Owner's Manual

Radiant conveyor toaster
Table of Contents

Advertisement

1
Overall Dimensions w/Wire Feeder - 13 610"H (34 5cm) x 15 192" W (38 6cm) x 17 982" D
(45 7cm)
2 Product Opening - 1 50"H (3 8cm) x 10 50" W (26 7cm)
3 Electrical Requirements (Single phase):
A 120 Volt, 1800 Watt, 15 Amp
B 208 Volt, 1800 Watt, 8 5 Amp
C 230/240 Volt, 1800 Watt, 7 8 Amp
D Cordset configuration
1
Each toaster equipped with three wire grounded cordset and standard three-prong
plug
2 In the U S : 120V uses NEMA 5-15P 208, 230/240V uses NEMA 6-20P
3 In Canada: 120V uses NEMA 5-20P
4 Net/Shipping Weight – 28 lb (12 7kg) / 33 lb (14 97kg)
1
Check Contents - refer to Figure 1, account for the following parts:
A Wire Feeder - inside Reflector Tray
B Reflector Tray - shipped in place
C Toast Drawer - shipped in place
D Instruction Manual - shipped loose
2 Position Wire Feeder
A Pull out Reflector Tray
B Rotate Wire Feeder
C Slide Reflector Tray back
D WARNING: Operating toaster without Reflector Tray reduces toasting capabilities
3 Toaster Placement
A Locate toaster near a grounded receptacle of the proper configuration (see below)
Plug the cordset directly into receptacle (DO NOT USE AN EXTENSION CORD)
1
In the U S : 120V uses NEMA 5-15R 208, 230/240V uses NEMA 6-20R
2 In Canada: 120V uses NEMA 5-20R
B Place toaster on flat surface providing following minimum clearances:
1
Base = one inch (provided with legs installed)
2 Side and back walls = two inches
3 Overhead = Enough space to allow adequate heat displacement
C Position toaster where customers will not contact any surface labeled "CAUTION
HOT"
1
Preparation
A Clean toaster thoroughly before first use (See cleaning instructions)
B Controls Familiarity
1
Main Power Switch (located on very bottom of control panel): There are two rocker
switches The bottom switch powers the unit "ON" It also turns on the bottom
element The top switch is a standby switch (upper heat switch) that runs the top
element When the standby switch is in the "ON" position the unit is at full power
When the standby switch is in the "OFF" position the unit is running at 50%
A Full Power: Flip both rocker switches to the right
B Power Off: Flip both rocker switches to the left
2 Conveyor Speed Control: Set knob to the three (3) position for warm-up
C Warm-up time: Allow five (5) minutes