Pulse Width Trigger Mode; Timing - Omron STC-MBS312POE Product Specifications And User's Manual

Gige vision, monochrome / color cmos poe camera, 3.2m / monochrome / color
Table of Contents

Advertisement

9.2

Pulse width trigger mode

In this trigger mode with positive polarity, the expose starts at rising edge of trigger signal and stops at falling edge
of trigger signal. The expose period is high states of trigger signal.
In this trigger mode with negative polarity, the expose starts at falling edge of trigger signal and stops at rising
edge of trigger signal. The expose period is low states of trigger signal.

Timing

Trigger signal
(Positive polarity)
Expose
Image out
Note: The exposure time is active pulse duration of trigger signal.
Please refers "Exposure Timing" for more details.
STC-MBS312POE / STC-MCS312POE
Product Specifications and User's Guide
No.18S113-03
30/70

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stc-mcs312poe

Table of Contents