Setup Menu Table; Self-Diagnosis Function - Sony MDS-S41 Operating Instructions Manual

Minidisc deck
Hide thumbs Also See for MDS-S41:
Table of Contents

Advertisement

Set up M enu Table
The following table provides an overview of the various Setup Menu items, including their parameters, factory settings,
and reference page(s) in the manual.
To access t he Set up M enu
While the deck is stopped, press MENU/NO twice to display "Setup Menu."
M enu item
Program ?
T.Mark
LS(T)
Auto
S.Space
P.Hold
Sleep
Rec
Adjustable in 2 dB steps.
*
To recall a f act ory set t ing
Press CLEAR while selecting the parameter.
Self -Diagnosis Funct ion
The deck's self-diagnosis function automatically checks the condition of the MD deck when an error occurs, then issues a
three-digit code and an error message on the display. If the code and message alternate, find them in the following table
and perform the indicated countermeasure. Should the problem persist, consult your nearest Sony dealer.
Three-digit code/M essage
C11/Protected
C13/REC Error
C13/Read Error
C14/TOC Error
C71/Din Unlock
44
Downloaded from:
https://www.usersmanualguide.com/
Function
Creates a program.
Turns Automatic Track Marking on or off.
Changes the trigger level for Automatic Track Marking.
Turns Auto Space and Auto Pause on or off.
Turns Smart Space and Auto Cut on or off.
Continuously displays the level of the strongest signal.
Turns the Sleep Timer function on or off.
Selects the recording mode.
Cause/Remedy
The inserted MD is record-protected.
, Take out the MD and close the record-protect slot (page 15).
The recording was not made properly.
, Set the deck in a stable surface, and repeat the recording procedure.
The inserted MD is dirty (with smudges, fingerprints, etc.), scratched, or substandard in quality.
, Replace the disc and repeat the recording procedure.
The deck could not read the TOC on the MD properly.
, Take out the MD and insert it again.
The deck could not read the TOC on the MD properly.
, Insert another disc.
, If possible, erase all the tracks on the MD (page 30).
The sporadic appearance of this message is caused by the digital signal being recorded. This will not affect
the recording.
While recording from a digital component connected through the DIGITAL IN connector, the digital
connecting cable was unplugged or the digital component turned off.
, Connect the cable or turn the digital component back on.
Parameters
Factory setting
Off/LSync
LSync
*
–72 to 0dB
–50 dB
Off/Space/Pause
Off
On/Off
On
On/Off
On
On/Off
Off
Stereo/Mono
Stereo
Reference page(s)
25
17
18
26, 27
17
16
38
14

Advertisement

Table of Contents
loading

Table of Contents