11. Safety devices

Type of protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Terminal protection
protection
program
Terminal protection
Compressor
program
protection
(Discharge temp.)
Type of protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Terminal protection
protection
program
Terminal protection
Compressor
program
protection
(Discharge temp.)
Protection form
Activate
Reset
Activate
Reset
Protection form
Activate
Reset
Activate
Reset
- 59 -
Model
AOHG07KGCA
250 V, 20 A
250 V, 5 A
125±25 °C
Fan motor stop
100±25 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
Model
AOHG12KGCA
250 V, 20 A
250 V, 5 A
125±25 °C
Fan motor stop
100±25 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
AOHG09KGCA
AOHG14KGCA