NuTone 757SNNT Manual

NuTone 757SNNT Manual

Decorative ceiling ventilator
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

DECORATIVE SERIES
CEILING VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by
the manufacturer. If you have questions, con-
tact the manufacturer at the address or tele-
phone number listed in the warranty.
2. Before servicing or cleaning unit, switch power
off at service panel and lock the service dis-
connecting means to prevent power from be-
ing switched on accidentally. When the ser-
vice disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by a qualified person(s) in accordance
with all applicable codes and standards, in-
cluding fire-rated construction codes and stan-
dards.
4. Sufficient air is needed for proper combus-
tion and exhausting of gases through the flue
(chimney) of fuel burning equipment to pre-
vent backdrafting. Follow the heating equip-
ment manufacturer's guideline and safety
standards such as those published by the
National Fire Protection Association (NFPA),
and the American Society for Heating, Refrig-
eration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hid-
den utilities.
6. Ducted fans must always be vented to the out-
doors.
7. NEVER place a switch where it can be
reached from a tub or shower.
8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently pro-
tected.
!
CAUTION
1. For general ventilating use only. Do not use
to exhaust hazardous or explosive materials
and vapors.
2. This product is designed for installation in
FLAT CEILINGS ONLY. Do not mount this
product in a wall.
3. The light fixture assembly must be mounted
to the fan housing assembly included with this
product. Do not mount the light fixture as-
sembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy
and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
5. Please read specification label on product for
further information and requirements.
TYPICAL INSTALLATIONS
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
HOUSING MOUNTED
TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
HOUSING MOUNTED TO "I" JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
Additional framing must be a 2x6 (minimum height), at least 9-inches long.
*
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
HOUSING MOUNTED
TO ADDITIONAL FRAMING
Discharge 90
*
HOUSING MOUNTED TO 2x4
Requires additional framing
for mounting tabs.
Discharge 90
*
HOUSING MOUNTED TO "I" JOIST
Requires additional framing
for mounting tabs.
Discharge 90
MODEL 757SNNT
Page 1
*
0
to joists.
*
TRUSS
0
to joists.
*
0
to joists.

Advertisement

Table of Contents
loading

Summary of Contents for NuTone 757SNNT

  • Page 1 MODEL 757SNNT Page 1 DECORATIVE SERIES CEILING VENTILATOR READ AND SAVE THESE INSTRUCTIONS WARNING TYPICAL INSTALLATIONS TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer.
  • Page 2: Typical Installations

    MODEL 757SNNT Page 2 TYPICAL INSTALLATIONS INSTALL THE HOUSING (continued) (continued) New Construction SUSPENDED CEILINGS Housing hung with wires - 3-point mount. INSTALL THE HOUSING 3. Set housing aside and drive nails partially into joist at the top of both keyhole marks.
  • Page 3: Connect The Wiring

    MODEL 757SNNT Page 3 INSTALL THE HOUSING CONNECT THE WIRING (continued) SCHEMATIC WIRING DIAGRAM L I G H T R E D B L U W H T L I G H T S W I T C H ( W H I T E )
  • Page 4: Bulb Replacement

    NUTONE ONE YEAR LIMITED WARRANTY NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
  • Page 5: Instalaciones Típicas

    MODELO 757SNNT Página 5 VENTILADOR DE CIELO RASO SERIE DECORATIVA LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA INSTALACIONES TÍPICAS PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIONES PERSONALES, OBSERVE LO SIGUIENTE: 1. Utilice esta unidad solamente de acuerdo con las instrucciones del fabricante.
  • Page 6: Instalación De La Cubierta

    MODELO 757SNNT Página 6 INSTALACIÓN DE LA INSTALACIONES TÍPICAS CUBIERTA (continuación) (continuación) Construcción nueva TECHOS SUSPENDIDOS Cubierta montada con cables. Montaje de tres puntos. INSTALACIÓN DE LA CUBIERTA 3. Coloque la cubierta a un lado e introduzca parcialmente los cla-...
  • Page 7: Conexión Eléctrica

    MODELO 757SNNT Página 7 INSTALACIÓN DE LA CONEXIÓN ELÉCTRICA CUBIERTA (continuación) DIAGRAMA ELÉCTRICO C O M M . R O J O A Z U L B L A N C O L A M P . Construcción existente L A M P .
  • Page 8: Uso Y Cuidado

    Esta garantía le da derechos legales específicos, y usted puede tener otros derechos que varían de estado a estado. Esta garantía reemplaza todas las garantías anteriores. Para calificar para servicio bajo esta garantía, usted debe (a) notificar a NuTone en la dirección o al teléfono abajo, (b) dar el número de modelo y la identificación de pieza y (c) describir el defecto en el producto o pieza.

Table of Contents