CHAPTER 3. FUNCTIONS
[1] FUNCTION
1. TEMPERATURE CONTROL CHARACTERISTIC
1.1. COOL operation
In the "COOL" mode, the thermostat circuit is controlled by five
thermostat lines (C1 thru C5).
Preset temperature (C )
1.2. DRY
In the "DRY" mode, the thermostat circuit is controlled by three
thermostat lines (D1 thru D3).
Preset temperature (C )
2. OPERATION MODES
2.1. COOL operation
The compressor turns on or off, at the thermostat lines C3 and
C4. The outdoor fan motor is also controlled with the compressor.
Preset temperature (C )
18 32
°
18 32
°
18 32
°
2.2. DRY
On the switch on, the compressor always starts to operate for 2
minutes with fan speed "DL".
The microcomputer reads the room temperature 2 minutes after this
first compressor operation.
This room temperature is set as the preset temperature
t
ti
ll
The preset temperature ranges from 18 C to 32 C. When the room
temperature is below 18 C, the preset temperature is set to 18 C,
and when the room temperature is over 32 C, the preset
temperature is set to 32 C.
Dry
operation
is
divided
Dehumidifying zone and Circulating zone) by thermostat lines (D1
to D3), and the compressor and the fan motor are controlled in
each zone as shown in Table.
Cooling zone
Dehumidifying zone
Circulating zone
3. FAN SPEED
Fan speeds are given by the indoor fan motor, "DL"~"HH" which
are available in the following operation mode.
Fan
Fan switch
speed
DL
DH
CL
COOL SOFT
CAL
CM
COOL LOW
CAH
CH
COOL HIGH
7
°
°
°
°
into
three
zones
18 32
°
Preset temperature (C )
Compressor
Fan speed
ON
ON
OFF
"DL" or OFF
AH-PG21
Fan switch
(r.p.m)
(AUTO)
800
DRY
890
800
840
COOL
980
1020
1170
°
°
(Cooling
zone,
"DH"
"DL"