This bulletin is provided for technical reference and service related updates. If you have any questions, comments or do not wish to receive these e-mails, please reply to this
e-mail or call the Service Technical Support Group 800 478-1244.
When planning for storage in cold weather climates. It is recommended to drain and remove all fluids from
the system during these conditions.
Rotate main valve to the 3 O'clock position.
Rotate rear spray valve to the 12 O'clock
position.
TI_WT5C_Winterizing.doc
WINTERIZING
If fluid is present in main tank, evacuate fluid using on board pump.
Place on level surface and raise trailer tongue using front jack stand to
highest point.
Locate and remove cleanout cover drain plug on pump end.
Page 1
Product Group: WATER TRAILERS Model: WT5C, WTE5C This bulletin is provided for technical reference and service related updates. If you have any questions, comments or do not wish to receive these e-mails, please reply to this e-mail or call the Service Technical Support Group 800 478-1244.
Page 2
Technical Information WINTERIZING CONTINUED Rotate the main valve back to the 9 O’clock position. Once fluid has appeared to have stopped draining, lower front trailer tongue using Once fluid has stopped draining, reinstall cleanout front jack stand to lowest position. cover drain plug on pump end.