Coolant Check; Monitoring Coolant Condition; Topping Up Of Coolant - Atlas Copco QAS 60 Pd S3A ESF Instruction Manual

Hide thumbs Also See for QAS 60 Pd S3A ESF:
Table of Contents

Advertisement

– Clean the adapter head sealing surface. Lightly oil
the gasket of the new element and screw the latter
onto the adapter head until the gasket is properly
seated, then tighten with both hands.
Never leave spilled liquids such as
!
fuel, oil, water and cleansing agents
in or around the generator.
– Top up the engine oil level.
– Run the engine for 1 minute and check the oil
level using the oil level dipstick.
5.4.3

Coolant check

5.4.3.1

Monitoring coolant condition

In order to guarantee the lifetime and quality of the
product, thus to optimise engine protection, regular
coolant-condition-analysis is advisable.
The quality of the product can be determined by three
parameters.
Visual check
– Verify the outlook of the coolant regarding colour
and make sure that no loose particles are floating
around.
Long service intervals
!
5-year drain interval to minimize
service
costs
(when
accordance with the instructions).
pH measurement
– Check the pH value of the coolant using a pH-
measuring device.
– The pH-meter can be ordered from Atlas Copco
with part number 2913 0029 00.
– Typical value for EG = 8.6.
– If the pH-level is below 7 or above 9.5, the coolant
should be replaced.
- 54 -
Glycol concentration measurement
– To optimise the unique engine protection features
of the PARCOOL EG the concentration of the
Glycol in the water should be always above
33 vol.%.
– Mixtures with more than 68 vol.% mix ratio in
water are not recommended, as this will lead to
high engine operating temperatures.
– A refractometer can be ordered from Atlas Copco
with part number 2913 0028 00.
In case of a mix of different coolant
!
products this type of measurement
might provide incorrect values.
5.4.3.2

Topping up of coolant

used
in
– Verify if the engine cooling system is in a good
condition (no leaks, clean,...).
– Check the condition of the coolant.
– If the condition of the coolant is outside the limits,
the complete coolant should be replaced (see
section "Replacing the coolant").
– Always top-up with PARCOOL EG.
– Topping up the coolant with water only, changes
the concentration of additives and is therefore not
allowed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

1104d-44 tg31104d-44 tg2

Table of Contents