a
b
c
FEATURES: REMOTE
THERMO-HYGRO SENSOR
(Model BHGR 228)
a
LED indicator
Flashes when the remote unit transmits a reading
b
Upper window
Displays temperature data
c
Lower window
Displays humidity data
d
[ RESET ]
Returns all settings to default values
e
C/ F slide switch
Selects between Centigrade ( C) and Fahrenheit ( F)
f
Channel slide switch
Designates the remote unit Channel 1, Channel 2 or
Channel 3

BEFORE YOU BEGIN

To ensure proper functioning of the BHGR618 follow this setup
procedure.
For best operation:
1. Assign different channels to different remote units.
2. Insert batteries in remote units before doing so for the main
unit (see instructions for battery installation).
3. Place the main unit as close as possible to the remote unit,
reset the main unit after installing batteries. This will ensure
easier synchronization between the transmission and reception
of signals.
4. Position the remote unit and main unit within effective
transmission range, which, in usual circumstances, is 65 to
100 feet.
d
e
f
Note that the effective range is vastly affected by the building
materials and where the main and remote units are
positioned. Try various set-ups for best result.
Though the remote units are weather resistant, they should be
placed away from direct sunlight, rain or snow.
BATTERY AND CHANNEL
INSTALLATION: REMOTE UNIT
The remote thermo-hygro sensor unit uses two (2) UM-4 or
"AAA" size alkaline batteries.
Follow these steps to install / replace batteries:
1. Loosen the screw on the battery door.
2. Select the channel number on the CHANNEL slide switch.
3. Select the temperature display unit on the C/ F slide switch.
4. Insert the batteries strictly according to the polarities shown
therein.
5. Replace the battery door and secure its screws.
Replace the batteries when the low-battery indicator of the
particular channel lights up on the main unit. (Repeat the
steps described in section ("BEFORE YOU BEGIN")
Note that once a channel is assigned to a remote unit, you
can only change it by removing the batteries or resetting
the unit.
BATTERY INSTALLATION: MAIN UNIT
The main unit uses two (2) UM-3 or "AA" size alkaline batteries.
Follow these steps to install / replace batteries:
1. Remove the screw to open the battery door.
2. Insert the batteries strictly according to the polarities shown
therein.
3. Select the temperature display unit on the C / F slide switch.
4. Replace the battery door and fasten the screw. Replace the
batteries when the low-battery indicator of the indoor
temperature lights up (Repeat the steps described in section
"BEFORE YOU BEGIN")