WALL OVEN
LWD3081ST
OVEN THERMISTOR
Remove the sensor from the oven.
(See page 19.)
Measure the resistance across the outer
terminals, as shown, at 77° F (25° C).
(R x 1000)
Normal
Replace if open or shorted.
DOOR SWITCH
Remove the switch from the oven.
(See page 22.)
Measure the resistance across the
terminals. (R x 1)
Plunger out should be continuity; plunger
in should be infinite resistance.
HALOGEN LAMPS
Often you can tell the bulb is bad by
looking at it. Check the continuity with an
ohmmeter if you have any doubt.
Page 36
TRAINING MANUAL
1090Ω ± 10%
TRAINING MANUAL