Samsung QB43R Service Manual page 104

Lfd monitor
Hide thumbs Also See for QB43R:
Table of Contents

Advertisement

1. The epcontrol folder is generated in root of USB memory, and created the file as follow.
1)
epcontrol_key
: Key file for using decoding.
2)
epcontrol_data
: Encrypted Log Data
3)
error_log
: This is a folder that saves error_log and
kernel_log by abnormal termination.
→ If abnormal termination is generated, the files are saved by
increasing number like this – error_log.1 ~ error_log.10.
→ You can check the last saved log by opening
error_log_count. It will be recorded with the final log
number.
→ (Reference) If the set is dead by saving log in USB,
error_log and kernel_log is saved not in USB but in set. If
you want to save a file from set to USB, reboot the set first
and then you can check the log file in error_log folder when
log storage function is executed.
In the case of needing log folder saved problem before
rebooting, you have to make a back-up.
→ All of the files in error_log folder is needed to decode by
using epcontrol_key
4)
backup
: back up file in epcontrol_key and
epcontrol_data is saved.
→ If the saved files in the old days are existed when storing
log is started, files move to backup folder.
→ Like epcontrol_key_backup1, epcontrol_data_backup1,
key and data file is saved, data file can be decoded by
using key file of same number key file.
info
5)
: save set_info file.
→ Save WatchDog On/Off, WatchDoc Count, AR Count
information in Factory mode
[Example of epcontrol folder contents by saving log]
[Example of error_log folder]
[Example of backup folder]
[Example of info folder]