Physical And Electrical Data; Dimensions - York LX Series Technical Manual

Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

PHYSICAL AND ELECTRICAL DATA

MODEL
Unit Supply Voltage
1
Normal Voltage Range
Minimum Circuit Ampacity
Max. Overcurrent Device Amps
Min. Overcurrent Device Amps
Compressor Type
Rated Load
Compressor
Amps
Locked Rotor
Crankcase Heater
Factory External Discharge Muffler
HS Kit Required with TXV
HS Kit Part Number (S1-2SA067*****)
Fan Diameter Inches
Type
Rated HP
Fan Motor
Rated Load Amps
Nominal RPM
Nominal CFM
Face Area Sq. Ft.
Coil
Rows Deep
Fins / Inch
Liquid Line Set OD (Field Installed)
Vapor Line Set OD (Field Installed)
6
Unit Charge (Lbs. - Oz.)
Charge Per Foot, Oz.
Operating Weight Lbs.
1. Rated in accordance with AHRI Standard 110-2012, utilization range "A".
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. Use S1-2SA067***** series kit. See Hard Start Kit Accessory Installation Manual.
5. For applications with non-standard vapor line sizes, see the "Applications & Accessories" section of this Technical Guide.
6. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet,
add or subtract the amount of refrigerant, using the difference in actual lineset length (not the equivalent length) multiplied by the per foot value.
‡ Adapter fitting must be field installed for the optional 1-1/8" line set.
Johnson Controls Ducted Systems
YEE18B21S
YEE24B21S
10.2
14.1
2
15
20
3
15
15
Scroll
Scroll
7.7
10.8
48.0
55.0
No
No
Yes
Yes
No
No
4
10106
10106
18
18
PSC
PSC
1/12
1/12
0.64
0.64
1000
1000
2000
2000
10.2
13.1
1
18
22
3/8
3/8
5
3/4
3/4
4 - 10
5 - 5
0.62
0.62
122
131
YEE30B21S
YEE36B21S
208-230V, 1 60Hz
187 to 252
16.4
19.6
25
20
Scroll
Scroll
12.3
14.7
63.0
75.0
No
Yes
Yes
Yes
No
10106
10106
22
PSC
PSC
1/8
1/4
0.8
1.3
1075
850
3200
4100
17.9
21.7
1
1
22
3/8
3/8
3/4
3/4
7-10
8 - 10
0.62
0.62
165
191

DIMENSIONS

Unit
Model
YEE18B21S
YEE24B21S
YEE30B21S
YEE36B21S
YEE42B21S
YEE48B21S
YEE60B21S
‡ Adapter fitting must be field installed for the optional 1-1/8" line set.
All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of base pan to top of fan guard.
Overall length and width include screw heads.
YEE42B21S
YEE48B21S
23.5
30
45
20
25
Scroll
Scroll
17.7
112.3
108.0
No
Yes
No
No
07006
07006
24
24
PSC
PSC
1/4
1.3
850
4100
4600
21.7
1
1
22
22
3/8
7/8
9 - 9
0.67
210
Dimensions
Refrigerant Connection
(Inches)
A
B
C
26-3/4
24
24
33-1/4
24
24
36-1/4
29-1/4
29-1/4
36-1/4
35-1/4
31-3/4
36-1/4
35-1/4
31-3/4
39-1/2
38
34-1/4
42-3/4
38
34-1/4
5855836-YTG-A-0220
YEE60B21S
24.5
29.1
45
50
25
30
Scroll
18.5
22.2
127.9
No
Yes
Yes
Yes
No
No
07006
26
26
PSC
1/4
1/4
1.3
1.3
850
850
4800
26.4
31.2
1
1
22
22
3/8
3/8
7/8
7/8 or 1-1/8
8 - 5
12 - 1
0.67
0.67 or 0.75
224
249
Service Valve Size
Liquid
Vapor
3/4
3/8
7/8
7/8
3